© EPS Stromversorgung in 2022, this information is subject to change without notice
76
30000800_manual_psb_10000_4u_30kw_en_04
3.11.4
Manual operation
3.11.4.1 Function selection and control
All the functions listed in
3.11.1 can be called on the touch screen,
configured and controlled. Selection and configuration are only
possible while the DC terminal is switched off.
►
How to select a function and adjust parameters
1.
While the DC terminal is switched off tap touch area
on the main screen. Note: this icon is locked as
long as resistance mode (R mode) is enabled.
2.
In the menu select the desired function by tapping on the list on the left-hand side. Depending on the choice of function
there follows a request to which value the function generator is going to be applied,
Voltage
or
Current
.
3.
Adjust the parameters as you desire.
4.
Adjust the overall limits of voltage, current and power, then continue with
.
5.
As last part of the configuration, global set values have to be defined which are considered as static values and come
into effect before and after the function run. Correct setup here is important, especially when running the function on
a master device of a master-slave system.
•
When intending to run a function exclusively in sink or in source mode, it’s recommended to set
the set values (I, P) of the opposite mode to 0.
•
The global limits of U, I and P become instantly active when coming to the main screen of the
function generator, because the DC terminal is then switched on automatically to settle the start
situation. This can be helpful when wanting a function shall not start at 0 V or 0 A. In case the
situation requires otherwise, the static values could also be set to 0.
6.
Exit the configuration and enter the main function generator screen with
.
Setting the various functions and their parameters is described below. After the function generator screen has been reached,
the function is ready to run. Before and while the function is running, some global and also some function related values can
be adjusted anytime.
►
How to start and stop a function
1.
The function can be
started
either by tapping
or if the
DC terminal is currently switched off by pushing the “
On/Off
”
button on the front.
2.
The function can either be
stopped
by tapping
or op-
erating the “On/Off” button. However, there is a difference:
a) The
button only stops the function while the DC
terminal remains ON with the static values in effect.
b) The “On/Off“ button stops the function and switches the
DC terminal off.
Any device alarm (power fail, overtemperature etc.), protection (OPP, OCP) or event with Action = Alarm
stops the function progress automatically, switches off the DC terminal and reports the alarm.