© EPS Stromversorgung in 2022, this information is subject to change without notice
60
30000800_manual_psb_10000_4u_30kw_en_04
3.5.8.4
USB logging file format
Type: text file in german/european or US american CSV format (depending on the selected setting)
Layout (default german format shown):
Legend:
U set
: Voltage set value
U actual / I actual / P actual / R actual
: Actual values
I set (PS) / P set (PS) / R set (PS)
: Set values I, P and R belonging to source mode (PS)
I set (EL) / P set (EL) / R set (EL)
: Set values I, P and R belonging to source mode (EL)
R mode
: Resistance mode activated/deactivated (also called ‘UIR mode’)
Output/Input
: State of the DC terminal
Device mode
: Actual regulation mode (also see
Error
: Device alarms
Time
: Elapsed time since logging start
Important to know:
•
R set and R actual are only recorded if “R mode” is active (refer to section
•
Unlike the logging on PC, every log start here creates a new log file with a counter in the file name, starting generally with
1, but minding existing files
3.5.8.5
Special notes and limitations
•
Max. log file size (due to FAT32 formatting): 4 GB
•
Max. number of log files in folder HMI_FILES: 1024
•
With setting
Start/stop
being
At DC on/off
, the logging will also stop on alarms or events with action
Alarm
, because they
switch off the DC terminal
•
With setting
Start/stop
being
Manual
, the device will continue to log even on occurring alarms, so this mode can be used
to determine the period of temporary alarms like OT or PF
3.5.9
The quick menu
The device offers a quick menu which allows for the quick access to often used features and modes being switched on or
off in the “Settings” menu. It can be opened by swiping up from the bottom screen edge or tapping the bar:
Overview: