Page 62
EPS Stromversorgung GmbH
Alter Postweg 101 • 86159 Augsburg
Germany
Fon: +49 821 / 570451-0
Fax: +49 821 / 570451-25
www.eps-germany.de
PSI 9000 2U Series
These device alarms can’t be configured and are based on hardware:
Alarm Meaning
Description
Indication
PF
P
ower
F
ail
AC supply over- or undervoltage. Triggers an alarm if the AC supply is
out of specification or when the device is cut from supply, for example
when switching it off with the power switch. The DC output will be
switched off.
Display, digital
interface
OT
O
ver
T
em-
perature
Triggers an alarm if the internal temperature reaches a certain limit.
The DC output will be switched off.
Display, analog &
digital interface
OTpre
O
ver
T
em-
perature
pre
warning
Triggers an event of type
WARNING
if the internal temperature reaches
a certain limit, lower than the one of
OT
. This event is intended to warn
the operator that an
OT
alarm is imminent.
Display, digital
interface
MSP
M
aster-
S
lave
P
rotection
Triggers an alarm if the master of an initialised master-slave system
loses contact to any slave unit or if a slave has not yet been initialised
by the master. The DC output will be switched off. The alarm can be
cleared by either deactivating master-slave mode or reinitialising the
MS system.
Display, digital
interface
► How to configure the device alarms
1.
While the DC output is switched tap the touch area
on the main screen.
2.
On the right side tap the down arrow to select “
2. Protect
”.
3.
Set the limits for the equipment alarm relevant to your application if the default value of 110% is unsuitable.
The set values can be entered using the ten-key tab. This will appear by tapping the touch area
“Direct input”.
The user also has the possibility of selecting whether an additional acoustic signal will be sounded if an alarm or
user defined event occurs.
► How to configure the alarm sound (also see “
„3.4.3. Configuration via MENU“
)
1.
While the DC output is switched tap the touch area
on the main screen
2.
In the menu page, tap “
HMI Settings”
3.
In the following menu page, tap “
Alarm Sound”
4.
In the settings page tap the button to select between alarm sound on or off and confirm with
.
3.6.2.1
User defined events
The monitoring functions of the device can be configured for user defined events. By default, events are deac
-
tivated (action = NONE). Contrary to device alarms, the events only work while the DC output is switched on. It
means, for instance, that you cannot detect undervoltage (UVD) anymore after switching the DC output off and
the voltage is still sinking.
The following events can be configured independently and can, in each case, trigger the actions NONE, SIGNAL,
WARNING or ALARM.
Event
Meaning
Description
Range
UVD
U
nder
V
oltage
D
etection Triggers an event if the output voltage falls below the
defined threshold.
0 V...U
Nom
OVD
O
ver
V
oltage
D
etection
Triggers an event if the output voltage exceeds the de-
fined threshold.
0 V...U
Nom
UCD
U
nder
C
urrent
D
etection Triggers an event if the output current falls below the
defined threshold.
0 A...I
Nom
OCD
O
ver
C
urrent
D
etection
Triggers an event if the output current exceeds the de-
fined threshold.
0 A...I
Nom
OPD
O
ver
P
ower
D
etection
Triggers an event if the output power exceeds the de-
fined threshold.
0 W...P
Nom