3.4.6
Manual adjustment of set values
The set values for voltage, current and power are the fundamental operating possibilities of a power supply and
hence the two rotary knobs on the front of the device are always assigned to two of the values in manual operation.
As a fourth value there is the internal resistance, for which the resistance mode (R mode) has to be activated in
„3.4.3. Configuration via MENU“
„3.2.4. Internal resistance regulation“
Set values can be entered manually in two ways: via
rotary knob
or
direct input
.
Entering a value changes it immediately and no matter if the DC output is switched on or off.
When adjusting the set values, upper or lower limits may come into effect. See section „3.4.4.
. Once a limit is reached, the display will show a note like “Limit: U-
max” etc. for 1.5 seconds next to the adjusted value.
►
How to adjust values with the rotary knobs
1.
First check whether the value to be changed is assigned to one of the rotary knobs.
The main screen displays the assignment as depicted in the figure to the right.
2.
If, as shown in the example, the assignment is voltage (U, left) and power (P, right),
and it is required to set the power, then the assignments can be changed by tapping
this touch area. A set of selection fields then appears.
3.
After successful selection, the desired value can be set within the defined limits.
Selecting a digit is done by
pushing the rotary knob which shifts the cursor right to left (digit will be underlined):
►How to adjust values via direct input:
1.
In the main screen, depending on the rotary knob assignment, values
can be set for voltage (U), current (I), power (P) or resistance (R) via
direct input by tapping on the set/actual value display areas, e.g in the
uppermost area of voltage.
2.
Enter the required value using the ten-key pad. Similar to a pocket
calculator the key
clears the input.
Decimal values are set by tapping the point key. For example, 54.3 V
is set with
and
.
3.
The display switches to the main page and the set values take effect..
3.4.7
Switching the main screen view
The main screen, also called status page, with its set values, actual values and device status can be switched
from the standard view mode with three or four values to a simpler mode with only voltage and current display.
The advantage of the alternative view mode is that actual values are displayed with
much bigger characters
, so
they read be read from a larger distance. Refer to
to see where to switch the view
mode in the MENU. Comparison:
Standard status page
Alternative status page