Page 10
EPS Stromversorgung GmbH
Alter Postweg 101 • 86159 Augsburg
Germany
PS 9000 2U Series
Fon: +49 821 / 570451-0
Fax: +49 821 / 570451-25
1.8.3
Specific technical data
1000 W
Model 2U
PS 9040-40
PS 9080-40
PS 9200-15
AC Input
Input voltage & frequency
90...264 V AC, 50/60 Hz
Input connection
1ph (L ,N, PE)
Input fuse (internal)
T16 A
Leak current
< 3.5 mA
Power factor
~ 0.99
DC Output
Max. output voltage U
Max
40 V
80 V
200 V
Max. output current I
Max
40 A
40 A
15 A
Max. output power P
Max
1000 W
1000 W
1000 W
Overvoltage protection range
0...44 V
0...88 V
0...220 V
Overcurrent protection range
0...44 A
0...44 A
0...16.5 A
Overpower protection range
0…1100 W
0…1100 W
0…1100 W
Temperature coefficient for set values Δ/K
Voltage / current: 100 ppm
Output capacitance (standard version)
~5440 μF
~5440 μF
~800 μF
Output capacitance (high speed version)
~86 μF
~86 μF
~40 μF
Voltage regulation
Adjustment range
0...40 V
0...80 V
0...200 V
Accuracy
(1
(at 23 ± 5 °C)
< 0.1% U
Nom
< 0.1% U
Nom
< 0.1% U
Nom
Line regulation at ±10% ΔU
AC
< 0.02% U
Nom
< 0.02% U
Nom
< 0.02% U
Nom
Load regulation at 0...100% load
< 0.05% U
Nom
< 0.05% U
Nom
< 0.05% U
Nom
Rise time 10...90%
ΔU
Max. 30 ms
Max. 30 ms
Max. 30 ms
Display: Resolution
„1.9.6.4. Resolution of the displayed values“
Display: Accuracy
(4
≤ 0.2% U
Nom
≤ 0.2% U
Nom
≤ 0.2% U
Nom
Ripple
(2
< 114 mV
PP
< 8 mV
RMS
< 114 mV
PP
< 8 mV
RMS
< 164 mV
PP
< 34 mV
RMS
Remote sensing compensation
Max. 5% U
Nom
Max. 5% U
Nom
Max. 5% U
Nom
Output voltage fall time (at no load)after
switching DC output off
-
-
Down from 100% to
<60 V: less than 10 s
Current regulation
Adjustment range
0...40 A
0...40 A
0...15 A
Accuracy
(1
(at 23 ± 5 °C)
< 0.2% I
Nom
< 0.2% I
Nom
< 0.2% I
Nom
Line regulation at ±10% ΔU
AC
< 0.05% I
Nom
< 0.05% I
Nom
< 0.05% I
Nom
Load regulation at 0...100% ΔU
OUT
< 0.15% I
Nom
< 0.15% I
Nom
< 0.15% I
Nom
Ripple
(2
< 3.7 mA
RMS
< 3.7 mA
RMS
< 2.2 mA
RMS
Display: Resolution
„1.9.6.4. Resolution of the displayed values“
Display: Accuracy
(4
≤ 0.2% I
Nom
≤ 0.2% I
Nom
≤ 0.2% I
Nom
Transient time after load step
< 1.5 ms
< 1.5 ms
< 1.5 ms
Power regulation
Adjustment range
0…1000 W
0…1000 W
0…1000 W
Accuracy
(1
(at 23 ± 5 °C)
< 1% P
Nom
< 1% P
Nom
< 1% P
Nom
Line regulation at ±10% ΔU
AC
< 0.05% P
Nom
< 0.05% P
Nom
< 0.05% P
Nom
Load regulation at 10-90% ΔU
OUT
* ΔI
OUT
< 0.75% P
Nom
< 0.75% P
Nom
< 0.75% P
Nom
Display: Resolution
„1.9.6.4. Resolution of the displayed values“
Display: Accuracy
(4
≤ 0.8% P
Nom
≤ 0.8% P
Nom
≤ 0.8% P
Nom
Efficiency
(3
~ 92%
~ 92%
~ 93%
(1 Related to the nominal values, the accuracy defines the maximum deviation between an adjusted values and the true (actual) value.
Example: a 80 V model has min. 0.1% voltage accuracy, that is 80 mV. When adjusting the voltage to 5 V, the actual value is allowed to differ max. 80 mV, which
means it might be between 4.92 V and 5.08 V.
(2 RMS value: LF 0...300 kHz, PP value: HF 0...20 MHz
(3 Typical value at 100% output voltage and 100% power
(4 The display error adds to the error of the related actual value on the DC output.