Never use the hydraulic breaker as a sledge hammer
to demolish material.
n
Never use the hydraulic breaker to move debris.
6.2.3 Breaking under water
Hydraulic breakers can be used for operating under wa-
ter.
bar
1.5-2
NOTICE
When operating under water the hydraulic
breaker must be fed with compressed air to keep the
area between the piston and the inserted tool free from
water. If the area between the piston and the inserted
tool gets filled with water, it may penetrate into the hy-
draulic oil system when the hydraulic breaker is started.
The air pressure must be 1.5-2 bar (22-29 psi) at the air
inlet on the breaker and the air consumption can be
found in "Technical data". Suitable air hose is a ¼ in. hy-
draulic hose with JIC connection. Contact your nearest
authorised workshop for further instructions.
6.2.4 Special applications
NOTICE
Always consult the Customer Center /Dealer in
your area in case of special applications- tunnelling, high
thermal load and underwater application.
You can contact your nearest authorised workshop for
further instructions.
7 Maintenance
It is essential that regular maintenance is performed to
maintain the breakers maximum efficiency.
Equipment that is insufficiently maintained can be dan-
gerous for both the operator and persons near the
breaker. Make sure that regular maintenance routines
with lubrication are followed to keep the equipment safe
and efficient.