Safety and operating instructions
14
© Construction Tools PC AB | 9800 1273 01 | 2020-04-03
Original Instructions
Hose connections
Left (As seen from operator's seat)
Water
Pressure to
breaker
Pressure
for Con-
tiLube II mi-
cro
Symbol
SB 702
G ¼ in.
G 1 in.
G ¼ in.
SB 1102
G ¼ in.
G 1 in.
G ¼ in.
Tightening torque for pressure and return hoses
SB 702
300 Nm (221 ft lbs)
SB 1102
315 Nm (232 ft lbs)
NOTICE
The tightening torques in the table above are
valid when the pressure and return hose are mounted di-
rectly on the hydraulic breaker's connection nipple. If the
pressure and return hose are connected with an addi-
tional connection nipple, another tightening torques must
be used.
5.2 Hydraulic oil
Normally the type of hydraulic oil the carrier is using also
works for the hydraulic breaker. When a hydraulic
breaker is connected to the carrier, the hydraulic oil will
get dirty faster. Check and follow the carrier's instruc-
tions for changing oil and oil filter. It is common to
change the oil filter more frequent when a hydraulic
breaker is installed.
SB hydraulic breakers are equipped with an oil drainage
plug to drain all oil before dismounting. This is to reduce
the risk of spilling oil.
NOTICE
When the SB breaker is delivered it contains
some mineral based hydraulic oil. Before connecting to
the carrier's hydraulic system, check which type of hy-
draulic oil the carrier is using. Mixing different types of
hydraulic oil may destroy the lubrication quality which
can lead to machine damage.
In order to protect the environment we recommend the
use of biologically degradable hydraulic oil.
Viscosity
Viscosity (permitted)
15-100 cSt
NOTICE
Always use clean oil and filling equipment.
5.3 Assembly
Circulate the hydraulic oil before connecting the ma-
chine. This is to make sure that the hydraulic oil is clean.
Use the same routine when changing a hydraulic oil
hose.
1. Connect the pressure and return hose.
2. Run the hydraulic oil through the carrier's oil filter for
approximately 3 minutes to make sure that the hoses
are clean.
WARNING
Falling breaker can cause injuries
u
Place the breaker in a safe position where it can not
fall over and cause damage.
Preparation
1. Place the breaker in a position where it is easy and
safe to mount the adapter plate.
NOTICE
Mount the breaker so that the accumulator
faces the operator's cabin, to reduce the risk of accu-
mulator damage.
Mounting the adapter plate
1. Place the adapter plate on the hydraulic breaker.
Содержание SB 1102