Safety and operating instructions
20
© Construction Tools PC AB | 98001365 01 | 2020-09-24
Original Instructions
5. Align the rock drill so that the drill steel touches the
required collaring point. Avoid small irregularities on
the surface, since they break easily and cause either
a wrong working angle or blank firing.
6. Move the throttle lever (B) forward a little, which
starts the water flushing, the percussion and rotation.
7. Press the rock drill firmly against the material to be
drilled. Turn the twist handle to push the rock drill for-
ward by means of the pusher leg. Increase to full
throttle when collaring is under control.
8. Adjust the feed force to ensure that the rock drill runs
regularly.
6.3.3 Stopping the rock drill
B
A
C
n
Pull the throttle lever (B) backwards. This stops the
percussion, rotation, and flushing water.
6.3.4 Start and stop the rock drill for Roof
Bolting version
A
n
Turn the throttle lever (A) uppwards to start, and
downwards to stop the rock drill when using roof bolt-
ing version.