8.8 Operating temperature too high
Cause
Remedy
By
Oil level in tank too low
Check oil level and top up oil
Carrier driver or work-
shop
Carrier pump delivery too high; a
constant volume of oil is squirted
out of the pressure relief valve
Check and correct motor speed of carrier
Drive the pump
Epiroc Customer
Center / Dealer in
your area
Pressure relief valve defective or
valve with poor characteristics
Fit new type-tested pressure relief cartridges or a more
precise pressure-limiting valve
Workshop or Epiroc
Customer Center /
Dealer in your area
8.9 The hydraulic compactor cannot be rotated
Cause
Remedy
By
Rotation motor/transmission de-
fective
Replace the defective parts
Epiroc Customer
Center / Dealer in
your area
Carrier defective
Check the
»Turn«
function of the carrier (Observe the Op-
erating Instructions for the carrier)
Carrier driver or Ser-
vice Department of
carrier manufacturer
8.10 Hydraulic compactor rotates by itself
Cause
Remedy
By
Internal leaks in hydraulic system
Check and repair the hydraulic system
Workshop