8 Troubleshooting
8.1 Hydraulic attachment does not work
Cause
Remedy
By
Pressure and tank lines swapped
Connect the hydraulic hoses correctly (see chapter
Hy-
draulic connections
)
Carrier driver
Check valve in pressure and/or
tank line closed
Open the check valve
Carrier driver
Oil level in tank too low
Top up oil
Carrier driver
Defective couplings blocking
pressure and tank lines
Replace defective coupling halves
Workshop
Faults in the electrical system of
the hydraulic attachment installa-
tion
Check electrical system of hydraulic attachment cutter in-
stallation and remedy defects
Workshop
Magnet on switch-on valve dam-
aged
Replace the magnet
Workshop
Operating pressure too low
Check the carrier engine speed, the pump delivery and
the pressure relief valve; check the operating pressure
Carrier driver or
Epiroc Customer
Center / Dealer in
your area
8.2 Tamper plate frequency too low
Cause
Remedy
By
Insufficient hydraulic oil delivery
volume
Correct the carrier engine speed, check the operation
pressure, check the carrier mode stages
Carrier driver
The connecting fitting in the pres-
sure and tank line has come
loose
Check the connecting fitting and tighten as required
Carrier driver
Check valve in pressure and/or
tank line partly closed
Open the check valve
Carrier driver
Flow resistance on oil filter or oil
cooler too high
Check the oil filter and oil cooler, clean or renew them
Carrier driver
Inside diameter of tank line too
small
Change the inside diameter: Observe the minimum inside
diameter! (see chapter
Technical specifications
)
Workshop
Return pressure too high
Check and lower the return pressure
Epiroc Customer
Center / Dealer in
your area
Hydraulic oil return to the tank via
a valve section
Not allowed!
Note:
The hydraulic oil return circuit must always be con-
nected directly to the tank or filter
Carrier driver or
Epiroc Customer
Center / Dealer in
your area
Hydraulic oil temperature in the
tank higher than 80 °C
Check the oil level in the hydraulic tank and top up as re-
quired
Carrier driver
Hydraulic oil pressure too low
Check the pressure; adjust as required; Fit new type-
tested pressure relief cartridges where necessary
Workshop