7.10 Changing the oil in the
PermanentLube system
The oil in the PermanentLube system must be changed
once a year.
n
Place timber support blocks on an oil pan.
n
Position the hydraulic compactor on timber support
blocks.
NOTICE
Environmental damage due to consumables
Motor oil is environmentally harmful and must not
penetrate the ground or enter water table or water
supplies.
u
Collect any dumped waste oil.
u
Ensure that containers filled with motor oil cannot
topple over and flow out, so that your working
area will not be polluted.
u
Observe all Safety and environmental protection
provisions when handling motor oil.
A
B
C
n
Remove the air breather valve (A) and drain plug with
seal (B) from rotor housing.
n
Tip the rotor housing and rest it on its side, so that
the oil runs out.
n
Restore the rotor housing to its upright position.
n
Fit the drain plug and seal (B) back in the rotor hous-
ing. Required tightening torque see chapter
Bolt
connections / Tightening torques
.
n
Remove the oil level indicating plug (C) and fill with
new oil via hole (A) until oil trickles from hole (C).
Type
Quantity
HC 150
0.6 l (0.16 gal)
HC 350
0.8 l (0.21 gal)
HC 450
0.9 l (0.24 gal)
Type
Quantity
HC 850
3.7 l (0.98 gal)
HC 1050
3.7 l (0.98 gal)
n
Fit both oil level indicating plug (C) and air breather
valve (A) back in the rotor housing. Required tighten-
ing torques see chapter
Bolt connections / Tighten-
ing torques
.