VGADVI Recorder Pro User
Guide
Verify RAID storage
Verify RAID storage
The rackmount VGADVI Recorder Pro can be optionally configured with storage configured in a RAID array.
Use the strategies described here to determine if you are using a RAID array and if it is in good health.
To check if the disks are configured for RAID:
1. Login to the Admin panel as
admin
.
2. Select the
Disk Check
link in the Configuration menu; the disk maintenance page opens.
3. Scroll to the Disk information section of the page.
4. If RAID is configured, the disk information contains a line item for /dev/md0. The RAID configuration
level is shown next in the /dev/md0 statistics.
To check RAID integrity:
1. Login to the Admin panel as
admin
.
2. Scroll to the Internal Storage section at the bottom of the menus on the left side of the page.
3. If the RAID configuration is sound, the internal storage section reports statistics for the storage, but
shows no errors.
4. If using RAID 0 and one of the disks is down, the following error is displayed. Rebuild or replace the
disks to recover.
320