CAUTION!

             

Before commencing any work on the electrical 

connections, you must first disconnect the thermostat 
from the mains. None of the 230V connections must  be 
live until the installation has been completed and the 
housing is closed. Only qualified electricians or authorised 
service staff are permitted to open the thermostat.
There are parts that may carry mains voltage behind the 
cover. The thermostat must not be left unsupervised 
when open. (Prevent non specialists and especially 
children from gaining access to it.)

Operating Instructions

Page 1 of 2

CRT2 Room Thermostat 

Battery Operated

4.  Installation

1.  Factory default settings

8. Resetting the thermostat

7. Button / Symbol description

6. Frost protection

9.  Keypad lock and unlock

2.  Specifications & wiring

Contacts: 

  Volt 

Free 

Temperature indicator: 

°C

Switching differential:  

0.4°C

In built frost protection: 

5°C

High and Low temp. limitation:  Off

5°C

OFF

Reset button

Set point increase

Set point decrease

Set button

On / Standby button

Room temperature

Heating ON symbol

3.  Mounting 

     

 Contents 

1.  Factory default settings

2.   Specification & wiring

3.   Mounting

4.   Installation

5.  Wiring diagram

6.   Frost protection

7.  Button / symbol description

8.   Resetting the thermostat

9.   Keypad lock and unlock

10.  High and Low temperature limitation

11.  Replacing the batteries

Prior to setting the thermostat, it is neccessary to 

complete all required settings described in this section.

5.  Wiring diagram

Important: Keep this document

Slacken the fastening screw on the bottom of the thermostat with a philips 

head screwdriver.
The thermostat is hinged and can be opened 180 degrees.

Mount the unit as described in section 3.

Wire the thermostat according to the wiring diagram.
Close the thermostat and tighten the fastening screw.

20170301_A

W1077_CR

T2_OpI

ns_JW

EPH Controls Ireland

Sitecast Industrial Estate, Pouladuff,
Cork, T12 W665, Ireland

[email protected]    www.ephcontrols.com

EPH Controls UK

Unit E4, Welland Business Park, Valley Way, Market Harborough, 
Leicestershire, LE16 7PS, United Kingdom

[email protected]   www.ephcontrols.co.uk

The mounting height should be 1.5 meters above the floor level.
The thermostat should be wall mounted in the room where the heating is to 

be controlled.
The place of installation should be chosen so that the sensor can measure the 

room temperature as accurately as possible.
Choose the mounting location to prevent direct exposure to sunlight or other 

heating / cooling sources when mounted.
The unit can be fitted to: 

1. Recessed conduit boxes

 

 

 

2. Surface mounting boxes

 

 

 

3. Directly on walls.

INTERNAL WIRING DIAGRAM CRT2

3 2 1

ON

OFF

COM

Frost protection is built into this thermostat, it is pre fixed at 5°C and is not 
adjustable.
It will only be activated when the thermostat is in the stand by mode     
and the room temperature reaches 5°C.

It is necessary to reset the thermostat prior to initial programming.
Press and hold the        button for 5 seconds.
dEL will appear on the screen.
Press the               button on the side of the thermostat.  

RESET

Set

To lock the keypad, press and hold the         and         buttons for 5 seconds.
 

will appear on the screen. The keypad is now locked.

To unlock the keypad, press and hold the         and         buttons for 5 seconds.
  

will disappear from the screen. The keypad is now unlocked.

Power supply: 

 

2xAA Alkaline Battery

Power consumption:   

2mW

Battery replacement:   

Once per year

Temp. control range:   

5 ... 35°C

Ambient temperature:  

0 ... 50°C

Contact rating: 

 

8A 250Vac

Dimensions: 

 

84 x 84 x 30mm

Temperature sensor:    

NTC 10K Ohm @ 25°C

Temperature indication: 

˚C 

Switching differential:  

Adjustable from 0.2/0.4/0.6/0.8/1.0˚C

Frost protection: 

 

Only operational in stand by mode