How your programmable thermostat works

2. Resetting the thermostat

1. LCD Symbol / button description

Manual

mode

Off mode
Program mode

Holiday mode
Time / date

Copy function

Boost mode

Automatic 

mode

(Back)

OK confirm button

Set point increase

Set point decrease

Reset button

Operating mode

Current program

Day / Month

Day of the week

Temperature

Heating on symbol
Keypad lock symbol

Current Time

(Boost to time)

     

 Contents 

1.  LCD symbol / button description

2.   Resetting the thermostat 

3.   Setting the date, time and operating mode 

4.   Factory program settings 

5.   Adjusting the program settings for 5/2d 

6.  Copy function 

7.   Temporary override

8.  Permanent override 

9.   Boost function

10.  Holiday function 

11.  Keypad lock and unlock

12.  Backlight mode selection 

13.  Frost protection

14.  Installer Menu (without OpenTherm® connected)

15.  Installer Menu (with OpenTherm® connected) 

Prior to setting the thermostat, it is neccessary to 

complete all required settings described in this section.

4. Factory program settings            

5/2d

3. Setting the date, time and operating mode

Mon-Fri

5/2D

P1

P2

P3

P4

P5

P6

06:30

08:00

12:00

14:00

17:30

22:00

21˚C

10˚C

10˚C

10˚C

21˚C

10˚C

21˚C

10˚C

10˚C

10˚C

21˚C

10˚C

21˚C

10˚C

10˚C

10˚C

21˚C

10˚C

21˚C

10˚C

10˚C

10˚C

21˚C

10˚C

21˚C

10˚C

10˚C

10˚C

21˚C

10˚C

Sat-Sun

08:00

10:00

12:00

14:00

17:30

23:00

Mon-Fri

7D

P1

P2

P3

P4

P5

P6

06:30

08:00

12:00

14:00

17:30

22:00

Sat-Sun

08:00

10:00

12:00

14:00

17:30

23:00

P1

P2

P3

P4

P5

P6

06:30

08:00

12:00

14:00

17:30

22:00

Everyday

24H

Press the ‘

TIME

’  button once, the year will begin flashing.

Press the          or          buttons to adjust the year.  

Press the ‘

OK

’ button. 

Press the          or          buttons to adjust the month.   Press the ‘

OK

’ button. 

Press the          or          buttons to adjust the day.  

Press the ‘

OK

’ button. 

Press the          or          buttons to adjust the hour.  

Press the ‘

OK

’ button. 

Press the          or          buttons to adjust the minute.   Press the ‘

OK

’ button. 

Press the          or          buttons to adjust from 5/2d to 7d or 24h mode.
Press the          or          buttons to turn DST (Day Light Saving Time) On or Off.
Press the ‘

AUTO

’ button or wait 5 seconds and the thermostat will return to 

normal operation.

5. Adjusting the program settings for 5/2d

Press the ‘

PROG

’  button once.

Programming for Monday to Friday is now selected.

Press the          or          buttons to adjust the P1 time.  Press the ‘

OK

’ button. 

Press the          or          buttons to adjust the P1 temp.   Press the ‘

OK

’ button. 

Repeat this process to adjust P2 to P6 times and temperatures. 
Press the ‘

OK

’ button.

1.1 LCD Symbol description

1.2 Button description

EPH Controls Ireland

[email protected]    www.ephcontrols.com

EPH Controls UK

[email protected]    www.ephcontrols.co.uk

Boiler 

Plus

20190930_CP4M_OpIns_JW

CP4M Room Thermostat 

 

Hardwired    Open Therm®    

CAUTION!

             

Before commencing, disconnect the 

device from the mains. There are parts that 
carry mains voltage behind the cover. Never 
leave unsupervised when it is open. (Prevent 
non specialists and especially children from 
gaining access to it.)
Never remove this product from the electrical 
baseplate. Disconnect from mains supply in the 
event of any damage to any buttons. Do not 
use sharp tools to push any button.

When the thermostat is in the AUTO mode, it will operate according to the 
times and temperatures that have been programmed. The user can select 
from 6 different programs per day - each with a time and a temperature. 
There is no OFF time, only a higher and a lower temperature setpoint. 
If the user wants the thermostat to be OFF at a certain time, set the 
temperature for this time to be low. The thermostat will turn ON if the room 
temperature is lower than the setpoint for the current period. 
Example: If P1 is set to be 21˚C at 6am, and if P2 is set to be 10˚C at 8am, the 
thermostat will look for the temperature to be 21˚C between 6am and 8am. 

Press the               button on the side of the thermostat.  

rst no

’ will appear on the screen.

Press the           button.

rst yes

’ will appear on the screen.

Press the ‘

OK

’ button to reset the thermostat. 

RESET