background image

 

 

NPower Series 

 

——Pure Sine Wave Inverter 

User Manual 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание NP1000-22(X)

Страница 1: ...1 NPower Series Pure Sine Wave Inverter User Manual...

Страница 2: ......

Страница 3: ...Designations of models 13 4 Schematic diagram for connections 14 5 Installation instructions 15 5 1 General installation notes 15 5 2Wire size breaker 15 5 3 Mounting 16 6 Protection 21 7 Troubleshoo...

Страница 4: ...Please read the related words carefully when you encounter the following symbols in the manual WARNING The entire system should be installed by professional and technical personnel TIP Indicates any p...

Страница 5: ...lem please contact the transportation company or our company in time CAUTION Follow the instructions before placing or moving the inverter CAUTION Make sure there isn t any arc danger in the operation...

Страница 6: ...wide input range but too high or too low input may cause problems even destroy the inverter CAUTION The wire connects between battery and inverter should be shorter than 3m the current density should...

Страница 7: ...ernal devices which may causeelectriferous Power cable connection is loose Screw or other spare parts inadvertently falls into the inverter Incorrect operation by untrained non professional or technic...

Страница 8: ...tenance work must post temporary warning sign or put up barriers to prevent unrelated personnel from entering the electrical connection or maintenance area Improper maintenance operation to the invert...

Страница 9: ...installation and easy operation It is suitable for AC load of household appliances power tools industrial equipment electronic audio and video and solar photovoltaic power generation system such as ve...

Страница 10: ...d low voltage reconnect voltage via the APP or PC software Set the inverter s ID via the APP or PC software to monitor several inverters The case is designed with the galvanized board with high streng...

Страница 11: ...8 2 Characteristics 1 NP260 NP1200 2 NP1500 NP3500...

Страница 12: ...400 22 X NP600 12 X NP600 22 X NP800 12 X NP1000 22 X NP1200 12 X NP1200 22 X Internal temperature is higher than 10 and the output power is higher than half of the continues output power of 25 NP2000...

Страница 13: ...22 X The output power is lower than 400W NP1200 12 X NP1200 22 X The output power is lower than 500W NP2000 42 T NP2500 22 T NP3000 22 T NP3000 42 T NP3500 42 T The output power is lower than 800W X...

Страница 14: ...11 Australia New Zealand European Terminal 3 Mode switch...

Страница 15: ...pin definition is shown below 1 5VDC 5 RS 485 A 2 5VDC 6 RS 485 A 3 RS 485 B 7 GND 4 RS 485 B 8 GND 5 LED indicator and buzzer Working indicator Fault indicator Buzzer Status Greensuper flashing Red o...

Страница 16: ...2 X 12VDC 400W NP400 22 X 24VDC NP600 12 X 12VDC 600W NP600 22 X 24VDC NP800 12 X 12VDC 800W NP1000 22 X 24VDC 1000W NP1200 12 X 12VDC 1200W NP1200 22 X 24VDC NP2000 42 T 48VDC 2000W NP2500 22 T 24VDC...

Страница 17: ...NP1500 NP3500 CAUTION Connect the DC input directly to the battery port is recommended DO NOT connect to the battery terminal of the controller Otherwise the charging frequency spikes of the controll...

Страница 18: ...according to the current density no higher than 5A mm2 In accordance with the National Electrical Code Article 690 NFPA70 For outdoor installation keep out of the direct sunshine and rain infiltration...

Страница 19: ...A Australia New Zealand E European M Universal Wire and breaker selection for AC output Models Wire size Breaker NP2000 42 T 1 5mm 2 16AWG AC 2P 10A NP2500 22 T 2 5mm 2 14AWG AC 2P 10A NP3000 22 T 2 5...

Страница 20: ...e cooling through housing if installed in a closed box 1 NP260 NP1200 2 NP1500 NP3500 Step3 Wiring WARNING The AC equipment shall be determined by the continuous output power of the inverter but the s...

Страница 21: ...CAUTION A fuse which current is 1 25 to 2 times the rated current of the inverter must be installed on the battery side with a distance from the battery not greater than 150mm Wiring order Ground Batt...

Страница 22: ...19 AC loads Accessories CAUTION Disconnect the system in the reverse order...

Страница 23: ...oad CAUTION If there are different types of loads it is suggested that turn on the loads with higher startup current first such as television then after the loads work stably turn on the loads with lo...

Страница 24: ...he output is OFF immediately Green indicator fast flashing Buzzer sounds NP 2 Ui 32 2V NP 4 Ui 64 4V Input overvoltage recover protection Models Recover value Default User defined Phenomenon NP 1 Ui 1...

Страница 25: ...uld auto recover for three times the first time delay 5s the second time delays for 10s and the third time delays for 15s After then the AC output would not auto recover after restarting the inverter...

Страница 26: ...oltage Measure the DC input voltage if the voltage is lower than16 32 64V Adjust the input voltage to restore normally Red indicator slowly flashing Buzzer sounds Overload Reduce the number of the AC...

Страница 27: ...ny troubleshooting or error indication Take corrective action if necessary Confirm that all the terminals have no corrosion insulation damaged high temperature or burnt discolored sign tighten termina...

Страница 28: ...ntinuous output power Rated input voltage 12VDC 24VDC Input voltage range 10 8 16VDC 21 6 32VDC output efficiency of80 rated power 81 84 Max Rated Efficiency 79 82 Max Efficiency 89 80W 90 100W No loa...

Страница 29: ...put power Rated input voltage 12VDC 24VDC Input voltage range 10 8 16VDC 21 6 32VDC output efficiency of 80 rated power 81 85 Max Rated Efficiency 79 84 Max Efficiency 90 100W 91 100W No load Current...

Страница 30: ...ut power Rated input voltage 12VDC 24VDC Input voltage range 10 8 16VDC 21 6 32VDC output efficiency of 80 rated power 81 85 Max Rated Efficiency 80 83 Max Efficiency 89 200W 92 160W No load Current 0...

Страница 31: ...inuous output power Rated input voltage 12VDC Input voltage range 10 8 16VDC output efficiency of 80 rated power 83 Max Rated Efficiency 81 Max Efficiency 92 100W No load Current 0 6A Rs485 Com Port 5...

Страница 32: ...inuous output power Rated input voltage 24VDC Input voltage range 21 6 32VDC output efficiency of 80 rated power 85 Max Rated Efficiency 82 Max Efficiency 92 200W No load Current 0 4A Rs485 Com Port 5...

Страница 33: ...tput power Rated input voltage 12VDC 24VDC Input voltage range 10 8 16VDC 21 6 32VDC output efficiency of 80 rated power 81 85 Max Rated Efficiency 78 84 Max Efficiency 92 200W 93 300W No load Current...

Страница 34: ...s output power Rated input voltage 48VDC Input voltage range 43 2 64VDC output efficiency of 80 rated power 89 Max Rated Efficiency 87 Max Efficiency 93 500W No load Current 0 3A Rs485 Com Port 5VDC 2...

Страница 35: ...tinuous output power Rated input voltage 24VDC Input voltage range 21 6 32VDC output efficiency of 80 rated power 89 Max Rated Efficiency 87 Max Efficiency 93 500W No load Current 0 8A Rs485 Com Port...

Страница 36: ...oltage 24VDC 48VDC Input voltage range 21 6 32VDC 43 2 64VDC output efficiency of 80 rated power 88 90 Max Rated Efficiency 86 89 Max Efficiency 94 500W 94 900W No load Current 0 8A 0 5A Rs485 Com Por...

Страница 37: ...s output power Rated input voltage 48VDC Input voltage range 43 2 64VDC output efficiency of 80 rated power 90 Max Rated Efficiency 89 Max Efficiency 93 900W No load Current 0 5A Rs485 Com Port 5VDC 2...

Страница 38: ...Environmental parameters Working Temperature 20 45 Full load Storage Temperature 35 70 Humidity 95 N C Enclosure IP20 Altitude 5000m Derating to operate according to IEC62040 at a height exceeding 100...

Страница 39: ...environment Battery voltage exceeds the input voltage limit of the inverter Damage caused by the working environment temperature exceeds the rated range Unauthorized dismantling or attempted repair D...

Страница 40: ...BEIJING EPSOLAR TECHNOLOGY CO LTD Tel 86 10 82894896 82894112 Fax 86 10 82894882 E mail info epsolarpv com Website www epever com...