![Epever iTracer IT4415ND Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/epever/itracer-it4415nd/itracer-it4415nd_user-manual_2417290035.webp)
31
green fast blink and
LCD displaying ‗OVD‘
larger than over
voltage disconnect
voltage (OVD)
high, and disconnect solar
modules.
Fault LED indicator
blink, LCD displaying
‗Current Err‘
Charging current in
three phases is
unbalanced
Disconnect solar modules
and restart the controller; if
the fault still exists, please
contact the supplier to make
maintenance
Fault LED indicator
blink, LCD displaying
‗Over Volt‘
Solar modular output
is too high
Check solar component
parameters matching; the
controller will disconnect the
input if the voltage is over
150V and will Recovery
below 145V
Fault LED indicator
blink, LCD displaying
‗Over Temp‘
Heat sinks
operational
temperature is quite
high to 85 ºC or above
The controller will
automatically stop working.
When the temperature is
below 75 ºC, the controller
will resume to work
Cannot connect to
the controller via
RS-485 or RS-232
RS-485 serial baud
rate setting error or
serial-USB adapter
incorrect configuration
Check serial baud rate is set
to 115200bps or not and
choose the right COM port; If
using a serial-USB adapter,
verify that the adapter
software is installed and a
serial COM port has been
mapped
Fault LED indicator
blink, LCD displaying
‗Over Load‘ or ‗Short
circuit
‘
Over load
①
or Short circuit
Please reduce the number of
electric equipments or check
carefully loads connection.
①
When load current reaches1.02-1.05 times 1.05-1.25 times, 1.25-1.35
times and 1.35-1.5 times more than nominal value, controller will
automatically turn off loads in 50s, 30s,10s and 2s respectively.
5.3 Maintenance
The following inspections and maintenance tasks are recommended at least
two times per year for best controller performance.
Make sure controller firmly installed in a clean and dry ambient.
Make sure no block on air-flow around the controller. Clear up any dirt and
fragments on radiator.
Check all the naked wires to make sure insulation is not damaged for
Содержание iTracer IT4415ND
Страница 1: ...iTracer ND series MPPT Solar Charge Controller User Manual Models IT4415ND IT6415ND...
Страница 2: ......
Страница 38: ...34 Figure6 2 Real Time Monitoring Figure6 3 Control Parameter...
Страница 45: ...41 Annex II Dimensions IT4415ND Dimensions Unit mm...
Страница 47: ......