F Battery Maintenance & Charging
Safety regulations for handling acid batteries
The truck must be parked and rendered safe before any operations on batteries are under
taken.Operational application
temperature
Fire protection measures:
Smoking and naked flames are not permitted when handling
batteries. No inflammable substances or spark-generating materials must be present or
stored within a distance of 2 meters of the truck parked for battery recharging. The location
must be well ventilated and fire fighting equipment must be kept ready.
Battery has high voltage and energy.
Do not short circuit.
Do not place any metal objects on the battery.
Do not put tools on the battery.
Battery type & dimension
All the batteries are maintenance free.
Battery type & dimension as follow:
Tuck type
Voltage/ Rated
capacity(V/AH)
Dimension
(mm)
Charger(A) Charging
time(h)
Internal
EPL1531
24/20
200*100*300
10A
2
•
•
•
•
1.1
1.2
DANGER
Charging the battery
Safety regulations for charging the battery
Before charging, check all cables and plug connections for visible signs of damage.
Before start and finish charging make sure power is turn OFF.
It is essential to follow the safety regulations of the battery and charging station
manufacturers
.
1.3
•
•
•
The charging environment temperature should be 5°C to 40°C.
i
NOTE
The truck can be operated at -20°C for a short period after it work above 5°C for a while.
WARNING
1.Battery life will be shortened if the battery is used for a long time at low temperature or
stored.
2.No charging below 0°C.
3.Only temporary cold store application permissible as the permissible battery
operating temperature is between 0°C and 40°C