INTRODUCTION
Thank you for purchasing a new EOTECH magnifier. These
magnifiers offer users of the Holographic Weapon Sight (all
models) the additional advantage of vastly improved target rec-
ognition and increased lethality at medium range distances. The
STS mount allows the user the ability to engage the enemy with confidence in a Close Quarters Battle (CQB)
situation or at distances out to 600 meters or more. This user manual describes the features of the EOTECH
Magnifiers and provides information on their use and maintenance. Please read the instructions carefully
before mounting and using the magnifier. Always practice proper firearm safety.
OPTIC CONFIGURATION
The EOTECH Holographic Weapon Sight (HWS)
product line has two different heights above the rail
based on user preference. For this reason, the mag-
nifier does not come preassembled to the mount.
It is user configurable based on the specific model
HWS it will be mounted behind. The 7mm riser,
included, may be required to align the magnifier
optical axis with the sight. Only HWS models with
side buttons or quick detach levers require the use of
the riser. For all other HWS models, the riser should
not be used.
The magnifier system can be configured to switch to the left or to the right based on shooting preference.
Typically, right handed shooters prefer the mount to switch to the right, and left handed shooters to the left.
To configure your HWS you will need a screwdriver (not included). If the riser is not used, the shorter screws
should be selected. The longer screws are used with the riser only. If the riser is being used, place the riser
on the optic mounting interface. Open the STS mount. Position the mount on the optic mount interface (or
riser) so it opens either to the left or right (based on preference). Insert each screw through the components,
and tighten securely. If using a torque wrench, the screws should be tightened to 24 in-lbs. Note: If you
purchased the magnifier as part of an HHS combo kit, the screw pack will not be included as the magnifer
comes preassmbled.
USER’S MANUAL FOR G-SERIES
MAGNIFIERS
This product is controlled under the Export Administration Regulations (EAR) ECCN 0A987, and may not be exported to a
foreign person, either in the U.S. or abroad, without a license or exception from the U.S. Department of Commerce
For use with G Series Magnifiers or HHS
systems containing the Switch to Side
(STS) mount. Images will vary by model.
SPECIFICATIONS
- Water-Resistant: 33 ft. (10m)
- Sealing: Fog-resistant internal optics
- Finish: Non reflective / Rubber coated
- Optical Axis Adjustment: Internal adjustment
- Switch Orientation: Ambidextrous mount
- Flip Orientation to allow left or right flip
- Rail Interface: 1” Weaver or MIL-STD-1913 with Quick Detach lock
Included
• Magnifier • Switch to Side (STS) Mount• 7mm Riser • 4 Screws
BASIC OPERATION
The G-Series magnifiers are designed to be used behind an EOTECH Holographic Weapon Sight (HWS). The
magnifier can be mounted directly behind the HWS. Simply switch the magnifier out of the way and operate
the sight. When used with HWS models 518, 558, 556, 517, EXPS or 516 HWS (with side button interface) the
user can easily operate the sight even with the magnifier in the locked position.
Positioning the Reticle:
Once the magnifier is installed properly behind the HWS, it may be necessary to re-zero the sight. This may
be due to the shooter’s ability to see the target and Point of Impact (POI) more accurately than without the
magnifier. Re-zeroing the sight will prevent a perceived shift in POI when going from no magnification to
magnification.
RETICLE POSITION ADJUSTMENTS
After zeroing or re-zeroing the sight, it may be necessary to reposition the reticle image into the center of the
magnifier window. This is aesthetic in nature and has no affect on the sight’s zero. Turn the horizontal and
vertical adjustments on the top or side of
the magnifier by hand, with a coin or a
flat head screwdriver to reposition reticle
to the desired position.
SWITCH OPERATION
To switch the magnifier to the side,
simply push the optic to the right or left,
depending on how it is mounted. To close
the mount, push the magnifier back into
its original position until a hard stop is
achieved.
ADJUSTABLE DIOPTER
The optic includes an adjustable diopter that allows the user to customize the
focus to their particular vision. This feature ensures a crisp, clean aiming dot
for more precision and shot placement. To adjust, simply grasp the diopter
with the thumb and fore finger and turn either clockwise or counter-clockwise
until a clear sight picture is achieved.
Note: Depending on the users vision, you may observe a small change to the
magnification during diopter adjustment.
M1960 Rev A
Figure 1
Figure 2
Figure 3