Setting up the heater
1
CAUTION! The heater weighs between 128 and 145 kg, depending on
the model. Four people should always move the heater, or a lifting de-
vice should be used.
Remove the transport protection and lift the heater from the pallet. Then
move it to the pre-defined installation site.
2
Unscrew the 3 adjustable feet 25–35 mm until the heater is level.
Use a spirit level if needed to ensure that the heater is level.
3
Remove all transport locks and protective films in the heater.
The safety slots are fixed with cable ties on the 20 and 24 kW models.
For the 30 and 36 kW models, the stone attachment is set inside the
heater and covered with protective film.
4
Remove the decoration ring, stone grate and, if necessary, stone attach-
ment.
Reattach these parts once electrical installation is complete.
5
If air is supplied from below, check that the slots are in the correct posi-
tion.
The slots are bent upward approx. 45° during heater manufacturing.
25–35 mm