![EOS SteamAttrac Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/eos/steamattrac/steamattrac_installation-and-operating-instructions-manual_2416973019.webp)
SteamAttrac - Installation and Operating Instructions
19
Identification
2.5.3
Side view with immersion heaters
Side view of steam generator (example: 6 kW version)*
* The 3 kW version is equipped with an immersion heater in the middle of
the tank side shown.
The vaporiser tank is insulated by a mineral wool matting and a protective
plate to shield the housing from the heat.
A
Safety temperature limiter
B
Screw-in immersion heater with
intake pipe for the capillary tube
sensor (safety temperature limiter)
C
Cable feed opening (mains
connection)
D
Feed-throughs (for lines to control
unit)
E
Button and indicator light
(descaling)
F
Shielding for vaporiser tank
G
Clamps for terminal connection and
control lines
H
Contactors
I
Intake pipe for the safety
temperature limiter’s capillary tube
sensor
B
C
D
G
B
I
A
E
H
F