Relay Box for Infrared Cabins - Installation Instructions
35
Installation
IR emitter at IR-3 starts when cabin is switched on
If you would like the IR emitter assigned to the IR-3 output to switch on
when the cabin is switched on, the DIP switches in IR3 must all be set to
OFF.
5.3 Connection diagram
The relay box is connected with a mains lead to the 230-V supply and fused
separately with 16 A. At minimum, a 16-A cut-out with c characteristic
must be used for fuse protection.
Connection example
To prevent overheating, install only infrared emitters or heating foils that
are designed and installed in such a way that they do not pose a fire hazard
IR-3 starts with cabin
1
2
3
4
5
ON
IR3
IR-Emitter 1
IR-Emitter 2
IR-Emitter 3
230 V AC 50 Hz
230 V AC 50 Hz
N
N
L
IR-1
IR-2
L
LIGHT
MAINS IR-3
L
N
N
N
L
L
Platine
STB
Saunabus
Sensor
24V DC
24V DC