Drill a hole in the cabin ceiling for the cable.
3
NOTICE Do not pull at the plug when routing the control line(s). Doing
so could damage the line. Attach the taught wire only to the cable.
Route the sensor cable through the hole.
4
Open the temperature sensor’s housing and connect the cable.
Connector pins for sensor bus
5
Screw the sensor to the cabin ceiling and close the housing.
Connecting the sensor line:
4.2.3 Installing cabin lighting
Lighting can be installed anywhere, however not near rising hot air. The
light output is set to inductive load by default, but light bulbs, halogen HV
bulbs and other resistive loads may also be connected to it. If required, the
light output can also be manually set to capacitive loads.
Setting the light output, see 7.4 Defining the light source manually,
Cabin lighting is not included in the scope of delivery. Observe the sepa-
rate installation instructions for lighting.
Light source requirements:
Minimal output 5 W
Resistive loads max. 100 W
Dimmable energy-saving bulbs max. 35 W
Light sources with conventional transformers max. 60 VA
Dimmable LED bulbs max. 60 W
A
White
(sensor bus)
B
Green
(sensor bus)
C
Brown (sensor bus)
A
B
C