EmoTouch 3 - Operating Instructions
97
Service settings
6
Set the following values in the same way:
a)
Set the interval: tap
. Value range: 30–480 min., increment:
30 min., factory setting: 60 min.
b)
Set the start time: tap
. Value range: 0:00–23:59, factory setting:
0:00. This setting deactivates the HOT function.
c)
Set the end time: tap
. Value range: 0:00–23:59, factory setting:
0:00. This setting deactivates the HOT function.
6.1.13 Setting the ECO runtime
This function allows you to define a window of time during which the
cabin temperature is lowered.
In the cabin, the ambient temperature is lowered as follows:
The window of time can be set to a value between 0 and 240 minutes in
30 minute-increments.
The setting is useful if there are intermissions in operation to prevent the
cabin from cooling down completely.
The ECO function is switched on via the control panel or via a push button
that is available as an option. It is automatically switched off after the
defined duration or ended by pressing the push button.
Setting the ECO mode runtime
1
Open the service settings.
See 6.1.1 Opening service settings,
2
Tap
and confirm the selection.
Calculation
:
T
ECO
= T
target
- ((T
target
- 30)/2)
T
ECO
= (65- (65-30)/2)
T
ECO
= 65-17.5
T
ECO
= 47.5°C.