16
Installation Instructions - EmoTouch 3
Mounting
EN
Mounting
This chapter describes how to install the relay box, the control panel and
the most important components.
Heat-resistant cables must be used to connect the sauna heater, vapor-
iser(s), lighting, fan(s) or other components if they are installed inside the
sauna cabin or in the cabin wall.
NOTICE
Damage due to incorrect mounting location
The control unit is not suitable for outdoor use.
It must be operated only inside buildings and may not be ex-
posed to environmental conditions such as extreme humidity
and moisture or the possible formation of condensation or cor-
rosive substances in the ambient air, as well as other weather
conditions.
Similarly, excessive cold and extreme exposure to sunlight must
be prevented.
Protect the unit accordingly if there is an increased risk of me-
chanical damage.
4.1 Power supply and data lines
All electrical installations and all connecting lines that are installed inside a
cabin must be suitable for an ambient temperature of at least 170°C and
protection class IPx4 or be suitable for use in a steam room (IP 65).
All lines must be routed in such a way that they are well-protected, e.g. in a
cable conduit.
NOTICE
Electronics malfunctions
Routing data and power supply lines together can lead to elec-
tronics malfunctions because, e.g. because the sensor will not be
detected.
Do not route sensor and sauna bus lines together with power
supply lines.
Route separate cable conduits.
Содержание 94 6505 00
Страница 71: ...EmoTouch 3 Installation Instructions 71...