REPLACING THE SENSOR
The Sensor is a non serviceable product. If damaged
the sensor must be replaced.
1. Turn power off at the power point.
2. Unscrew the fixing screws from the panel.
The existing silicone seal may have to be cut
to free the sensor, do this carefully. All sealing
compounds such as silicon should be removed
from the wall surface.
3. Pull the sensor out from the mounting block
carefully and access the plug and socket
connection. Unplug the line plug and socket
and leave the cable securely out of the conduit.
Replace the transformer or solenoid cable at this
time if necessary.
Disconnect spout from water supply and
dismantle from sensor plate. Reinstall onto new
sensor plate.
4. Connect the new sensor. Feed the cable back
into the conduit.
5. Apply a thin bead of silicon sealant on behind
the plate along the top and side edges, to seal
the unit to the wall.
6. Fix the sensor panel back onto the mounting
block using the existing screws.
REPLACING THE TRANSFORMER
The Transformer is a non serviceable product. If
damaged the transformer must be replaced.
1. Turn power off at power point and unplug the
transformer.
2. The transformer comes standard with 4.5 metres
of cable. This cable is connected to the sensor.
3. Take note of the installation, firstly to determine
if additional cable extensions are required
(additional to the 4.5 metres) and secondly to
see if cable access is difficult or if the cable is
fed through a conduit. If the cable is in a conduit
then a lead or leads may be required to be tied
to the existing cable before it is removed so the
new cable can be pulled back through.
4. Slowly pull the cable through to the sensor.
Remove the old transformer and cable.
5. Connect the new transformer cable to the sensor
connector cable. Re-install the sensor.
6. Plug the 24 V DC transformer into the power
point.
7. Turn on the power to the unit and test the unit.
CLEANING
Enware Product should be cleaned with a soft damp
cloth using only mild liquid detergent or soap and
water. Do not use cleaning agents containing a
corrosive acid, scouring agent or solvent chemicals.
Do not use cream cleaners, as they are abrasive.
Use of unsuitable cleaning agents may damage the
surface. Any damage caused in this way will not be
covered by warranty.
IMPORTANT:
Before fixing the sensor plate to wall,
apply a thin bead of silicone sealant
behind the plate along the top and
side edges. Ensure that the plate is
thoroughly sealed to the wall and
that not water can get in behind the
plate.
Any water entering behind the
sensor plate will cause damage
to sensor components and void