Technical data 

Operating voltage: 

0-5 VDC 

Internal resistance at room temperature: 

12.5 Ohm 

Operating current (typical): 

0-300 mA 

Absolute maximum current: 

400 mA 

Maximal recommended power input: 

1.1 W (300 mA) in continuous operation 
2.0 W (400 mA) short term (<1 minute) 

Inductance of the motor: 

10 Hz: 3.5 mH 

1 kHz: 0.8 mH 

50 Hz: 2.9 mH 

10 kHz: 0.6 mH 

100 Hz: 2.5 mH 

100 kHz: 0.4 mH 

Connecting the lens 

All EL-10-30-Series lenses have an electro-magnetic motor, which is driven by current. The lens will only work 
with the correct polarity of the current. False polarity will not damage the lens. 

EL-10-30 (compact version) 

The EL-10-30 has a simple copper cable connection. The correct polarity is shown in Figure 1: 

 

Figure 1: Connection of the EL-10-30. The colored cable is the  

positive terminal and the copper cable is the negative terminal. 

EL-10-30-C (C-mount version) 

The EL-10-30-C has an FPC connection compatible with Molex 0.5mm pitch 6 way FPC backflip connector (P/N 
503480-0600).  An adaptor board with integrated connector is included for easy soldering. The connector on 
the adaptor board has top and bottom contacts so it is important that once orientation is established it must 
be maintained. 

The EL-10-30-C also features an integrated NXP SE97B temperature sensor with 256 bytes of memory – the 
sensor is addressable via the pins as detailed below:   

 

         

 

Figure 2: Connection of the EL-10-30-C (Orientation looking at exposed Cu tracks) 

Pinning 

Position 

Function 

SE97B Pins 

SE97B Gnd 

1-4 

- (EL-10-30-C)  - 

+(EL-10-30-C) 

SE97B SDA 

SE97B SCL 

SE97B Power 

Copper cable 

– 