EnvisaLink S5401D  

DSC Compatible Serial Interface Module 

 
 
 
 
 
 

Developer’s Guide Version 1.0 

 
 
 
 
 

 
 
 
 

Содержание EnvisaLink S5401D

Страница 1: ...1 EnvisaLink S5401D DSC Compatible Serial Interface Module Developer s Guide Version 1 0...

Страница 2: ...3 3 S5401D Module Serial Connection 3 4 Communications Protocol 4 5 Application Originated Commands 5 6 S5401D Originated Commands 7 7 Special USER MASTER Code Requirements 9 8 Special Considerations...

Страница 3: ...ansmissions For information on each command refer to the command tables on pages 3 to 7 2 Developing Applications You can incorporate S5401D API commands in any application that can send and receive h...

Страница 4: ...ements are for each command Some commands like the User Closing have space holding zeros In this case all 4 digits are sent even though this module ever uses only two CKS Checksum The checksum is calc...

Страница 5: ...will attempt to arm the selected partition by using a User Code This is equivalent to entering a User Code while the partition is in the Ready mode 033 7 Partition 1 8 Code 4 6 digit Partition Disarm...

Страница 6: ...the module and the module will then send command 900 to tell the user to enter an access code The Code Send command transfers this code NOTE The code entered will be sent to the partition that sent th...

Страница 7: ...nsor this command displays the exterior temperature and the thermostat number NOTE The three digit temperature is a decimal representation of a signed byte 0 255 representing 127 to 127 degrees MSB is...

Страница 8: ...Delay in Progress A partition is in Exit Delay 656 1 Partition 1 8 Entry Delay in Progress A partition is in Entry Delay 657 1 Partition 1 8 Keypad Lock out A partition is in Keypad Lockout due to to...

Страница 9: ...be sent to perform the required action The code should be entered within the window time of the panel 900 0 NOTES 1 It is possible that when using a PC5020 Power 864 panel the very first command after...

Страница 10: ...r up the S5401D is not immediately aware of state of all the partitions nor the zones It is only when the S5401D detects a change in the state that it will know the true state and issue the appropriat...

Страница 11: ...Keybus Busy Lockout The panel is currently in Keypad Lockout too many disarm attempts 17 Keybus Busy Installers Mode Panel is in installers mode most functions are unavailable 18 Keybus Busy General B...

Страница 12: ...12 NOTES...