PIV & MIV AIR SOURCE / INLINE

VENTILATION UNIT INSTALLATION GUIDE

AFTER INSTALLATION THE END USER SHOULD 

KEEP THIS GUIDE FOR FUTURE REFERENCE

DO NOT THROW AWAY

Содержание MIV AIR SOURCE

Страница 1: ...PIV MIV AIR SOURCE INLINE VENTILATION UNIT INSTALLATION GUIDE AFTER INSTALLATION THE END USER SHOULD KEEP THIS GUIDE FOR FUTURE REFERENCE DO NOT THROW AWAY...

Страница 2: ...unobstructed path away from any smoke detectors If the diffuser cannot be repositioned up to two sides can be closed using the plastic blanking plates In this configuration the open sides must face a...

Страница 3: ...unit must be able to be disconnected from the mains supply after installation When wiring the unit the included unswitched fuse spur should be incorporated in the fixed wiring The power supply cable r...

Страница 4: ...rce Inline 01423 859 395 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL US ON 3 Diagrams PIV AIR SOURCE 200 mm 406 mm 479 mm 406 mm 479 mm 100 mm MIV AIR SOURCE 406 mm 576 mm 150 mm to at...

Страница 5: ...AFTER INSTALLATION THE END USER SHOULD KEEP THIS GUIDE FOR FUTURE REFERENCE DO NOT THROW AWAY 4 PIV 200 mm 406 mm 150 mm 576 mm MIV INLINE 100 mm 576 mm 150 mm 406 mm 200 mm 406 mm 406 mm 100 mm...

Страница 6: ...2 Airflow 2 3 Airflow 3 4 Airflow 4 5 Temperature 190 C 6 Temperature 190 C 7 Temperature 250 C 8 Top button 9 Numeric Display 10 Bottom button Use one of three options to connect the inline duct to t...

Страница 7: ...UTURE REFERENCE DO NOT THROW AWAY 6 WIRING The local isolator must be connected to the mains as part of the fixed wiring Connect the N L and E cores of the power cable to the matching terminals on the...

Страница 8: ...am pads 4x Washers 4x Screws 10g x 3 4x Screws 10g x 1 5 4x Screws 8g x 1 5 panhead 4x Screws 8g x 1 countersunk 4x Plasterboard plugs 2x 200mm duct fixings 1x 150mm duct fixing MIV Air Source box con...

Страница 9: ...hrough the loft is undamaged Seek building advice if any are damaged or broken Repair any ceiling gaps which allow air leakage into the loft Ensure any loft water storage tanks are covered and sealed...

Страница 10: ...s two 100mm diffusers to provide airflow to separate locations within the building It is normally required for applications where a The hallway is small b Limited heating is available c The loft hatch...

Страница 11: ...below the required ceiling diffuser position and check the ceiling below and loft space above are unobstructed 2 a For PIV units mark a 222mm diffuser hole using the template 2 b For MIV units mark tw...

Страница 12: ...battens using the four 10g x 1 5 screws Battens not supplied 4 b Position the unit with anti vibration pads and washers onto the loft ceiling joists as in the diagram 4 c Screw the unit to the ceiling...

Страница 13: ...diffuser and seal the connection using the fixings supplied 7 Insert the diffuser spigot into the hole then fix it in place Use the four plasterboard plugs and four 8g x 1 5 panhead screws do not use...

Страница 14: ...the unit 2 Connect to the filter with a section of flexible duct approximately 300mm long not supplied The connection must be removable to allow the filter to be replaced Connect this to an external...

Страница 15: ...6 Use two of the 8g x 1 screws to attach the spur to a loft joist 11 Non remote control units can be wired to a heater enable switch included Connect it to the heater enable cable and fit it in an acc...

Страница 16: ...SMOKE 125 PIV smoke kit with 1x 125mm diffuser KIT PIV SMOKE 150 PIV smoke kit with 1x 150mm diffuser KIT PIV SMOKE 200 PIV smoke kit with 1x 200mm diffuser KIT MIV SMOKE 125 MIV smoke kit with 2x 12...

Страница 17: ...AFTER INSTALLATION THE END USER SHOULD KEEP THIS GUIDE FOR FUTURE REFERENCE DO NOT THROW AWAY 16 SMOKE ALARM WIRING...

Страница 18: ...234 hours Wireless Remote Control To indicate the current status of the unit Press the remote control button once and the LEDs will light up according to the current status of the unit To modify the a...

Страница 19: ...ch front cover The battery is located on the back of the cover Battery type 3V Lithium CR2032 The switch will remain paired with the unit after battery replacement Ensure the new battery is inserted w...

Страница 20: ...ir flow rate l s a Power usage Watts b Total energy cost per year c d 1 22 3 3 94 2 29 4 5 26 3 35 5 6 57 4 43 8 10 51 Performance Figures PIV AIR SOURCE House size setting Max air flow rate l s a Pow...

Страница 21: ...0 15 per kWh d Figures calculated at incoming air temperature below 19 degrees C House size setting Max air flow rate l s a Power usage Watts b Total energy cost per year c d 1 28 2 7 3 55 2 38 3 8 4...

Страница 22: ...fuser 1DIFEVLSML1 Fixing kit FIXINGKITEVL R Spares Accessories Maintenance The PIV and MIV Air Source and Inline units are designed to operate for 5 years before requiring a full service It is recomme...

Страница 23: ...tformaintenance within the first 5 year period other than general cleaning The warranty covers any defect or break down that arises due to faulty materials or construction Please note that a receipt w...

Страница 24: ...and appearance without notice We want to hear from you Your feedback is important to us as we strive to improve our products services and overall customer experience Please email us to help us serve y...