Pre-conditioning cargo and container
When using the internal pre-conditioning program, the pre-conditioning can be started immediately, or set to be
completed within a specified number of hours (2–72 hours).
4.4.2.2.1 Pre-condition using the internal pre-conditioning program
Pre-conditioning to +5 °C (+41 °F) at an ambient temperature of -5 to +25 °C (+23 to 77 °F) takes maximum one
hour. Pre-conditioning outside this ambient temperature range will take more time.
If the container is connected to a power outlet during pre-conditioning, no battery power is consumed.
Fig. 12 Make sure the doors are closed
1.
Make sure the container doors are closed.
2.
On the shipment status overview, press
to enter
Container Settings
.
3.
Select
Set Temperature
.
NOTE!
The
Set Temperature
screen is active for one minute. If the display returns to the shipment status
overview before the new set temperature has been confirmed, the setting is not saved.
4.
Set the applicable temperature using
and
and press
to confirm. A prompt to start pre-
conditioning will be shown.
5.
To start the pre-conditioning immediately: Select
Now
and press
to initiate the pre-conditioning. The
display shows
Temperature control PRE-CONDITIONING
.
6.
To start the pre-conditioning later:
6a.
Select
Set Timer
.
6b.
Set the total number of hours remaining until the pre-conditioning shall be completed, using
and
. The timer interval is 2–72 hours.