PERIODIC MAINTENANCE

NOTE: Periodic inspection and preventative maintenance 
of your total heating system is important for efficient and 
safe operation. Your heating contractor can service your 
humidifier when he services the HVAC system.

The distribution tray above the water panel should be 
inspected annually and cleaned of excess mineral deposits. 

• Use our pro locator at: www.enviroaireiaq.com/find-a pro

• If none of the above is successful and you still need 
information, please feel free to contact us at: www.
enviroaireiaq.com/contact-us

If your humidifier is equipped with a Digital Humidifier 
Control with water panel change indicator, after replacing 
the water panel, turn the control knob to the “Test/Reset” 
position until the “Humidifier On” light blinks to reset its 
timer. (Blower must be operating and HVAC calling for heat.) 
Be sure to turn the control knob back to it’s original setting. If 
the “Humidifier On” light continues to blink, your humidifier 
is in Test mode. 

DO NOT LEAVE THE CONTROL IN TEST 

MODE OR HUMIDIFIER WILL NOT OPERATE.

REQUIRED MAINTENANCE INSTRUCTIONS

 

†

CAUTION

 

Sudden operation may cause personal injury or 
property damage. Turn Humidifier Control to “OFF” or 
lowest setting before servicing. 

1. Note Humidifier Control setting and turn dial to the “OFF” 
position.

2. Turn off water supply. Turn the integral bypass damper (3) 
to the SUMMER position.

3. Press the tabs in the latches on the top and bottom of front 
cover (1) and pull cover off base with both hands. Set aside.

4. Carefully pull the plastic feed tube (2) out of the distribution 
tray (5) at the top of the water panel evaporative assembly 
(4). Pull this assembly out by grasping at top and tipping out.

5. Unsnap the distribution tray (5) from the scale control 
insert (8). Lightly scrape out or brush off any mineral deposits, 
being careful not to stretch or loosen the synthetic fabric 
liner. Soaking the tray in vinegar or a lime-removing agent 
is helpful when trying to remove stubborn mineral deposits. 

6. Slide the water panel evaporator (7) out from the scale 
control insert (8) and dispose of the water panel. Clean the 
scale control insert of mineral deposits. Replace the Water 
Panel evaporator. Slide the water panel evaporator back 
into the scale control insert with the colored spot up and 
snap the distribution tray (5) back into place.

7.  Inspect the plastic feed tube (2) by gently flexing it and 
looking for cracks or signs of wear. Replace tube if it is 
cracked, brittle, or has been damaged.

8. Reinstall the Water Panel evaporative assembly (4) into 
the humidifier by fitting its drain into the round receptacle at 
the base of the humidifier. Push the assembly in at the top 
until it snaps into place. Push the end of the feed tube back 
firmly into the distribution tray and replace the front cover.

Содержание Bypass EA-655

Страница 1: ...Bypass EA 655 Humidifier Bypass Model EA 655 Humidifier Owner s Manual...

Страница 2: ...cing an invigorating comfortable day combines just the right temperature and the right amount of moisture EnviroAire IAQ humidifiers employ the same principle with refinements to give you the optimum...

Страница 3: ...ercentage of what the air can hold Warm air can hold more moisture than cold air can The control has lights which indicate humidifier operation when the Water Panel needs to be replaced and when servi...

Страница 4: ...lowing page The RH in your home will now be accurately controlled to meet your needs and should not need further adjustment during future heating seasons Make note of the dial setting in the event you...

Страница 5: ...r TEST RESET The Test Reset feature allows the humidifier operation to be checked even if there is no call for humidity See Check the Humidifier Operation ADDITIONAL INFORMATION Your humidifier is a p...

Страница 6: ...casion indoor moisture producing activities such as clothes drying cooking showers etc may raise the RH level higher than it should be even though the EnviroAire IAQ humidifier is not operating Tellta...

Страница 7: ...2 Turn off water supply Turn the integral bypass damper 3 to the SUMMER position 3 Press the tabs in the latches on the top and bottom of front cover 1 and pull cover off base with both hands Set asi...

Страница 8: ...5 year period by you to your original supplier together with the model number and installation date of the humidifier THIS WARRANTY SHALL NOT OBLIGATE ENVIROAIRE IAQ FOR ANY LABOR COSTS AND SHALL NOT...

Отзывы: