background image

PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE 

OF THIS PELLET-BURNING ROOM HEATER. FAILURE TO FOLLOW THESE 

INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY 

OR EVEN DEATH.

Contact your building or fire officials about restrictions 

and installation inspection requirements in your area. 

W

AR

RA

NT

Y R

EG

ISTR

AT

IO

N

enviro.com/warranty

M55C-FS-2

F R E E - S T A N D I N G   P E L L E T   S T O V E

OWNER’S MANUAL

  Version Française: www.enviro.com/fr.html

50-2100

C# 4001609

Содержание M55C-FS-2

Страница 1: ...Y DAMAGE BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area W A R R A N T Y R E G I S T R A T I O N e n v i r...

Страница 2: ...es to Combustibles 16 Levelling Leg Adjustment 16 Thermostat Installation 16 Vent Termination Requirements 17 Outside Fresh Air Connection 18 Exhaust and Fresh Air Intake Locations 18 Mobile Home Inst...

Страница 3: ...between cleaning CLINKERING clinkers are silica sand or other impurities in the fuel that will form a hard mass during the burning process This hard mass will block the air flow through the Burn Pot...

Страница 4: ...ood pellet has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or otherwise operate this pellet heater in a manner inconsisten...

Страница 5: ...you need to clean to be safe OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume spillage and for proper and safe operation of the pellet stove Also en...

Страница 6: ...earing capacity if existing construction doesn t meet load capacity suitable measures e g load distributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM...

Страница 7: ...15 5KW hr Table 1 M 55C FS Specifications Description Fuel type Residential Pellet Heater 6mm dia Pellets wood corn wheat barley Voltage Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hoppe...

Страница 8: ...e that is the set point Hold Trim Button down and press the UP or DOWN Heat Level Arrow to adjust setting 3 Light is the default setting Depending on Fuel quality Ignition problems may occur at higher...

Страница 9: ...will pulse at the same interval as the feed auger When the start up sequence is complete the unit will ramp up in two 2 minute intervals until it has reached the designated heat setting Once a fire h...

Страница 10: ...is designed to operate within a negative pressure range that may only be adjusted by a qualified technician This can be measured using a Magnahelic pressure gauge once the unit has been running on hea...

Страница 11: ...ire grate and remove it 3 The agitator locks at the right rotate the top of the agitator towards the back of the firebox to unlock it slide it to the left and lift it out of the burn pot liner 4 Lift...

Страница 12: ...R GASKETS Weekly After extended use the gasketing may come loose To repair this glue the gasketing on using high temperature fiberglass gasket glue available from your local dealer This is important t...

Страница 13: ...nce you are finished using the pellet appliance for the season unplug the stove for added electrical protection It is very important that the stove be cleaned and serviced as stated above CLEANING PAI...

Страница 14: ...carpet If it is to be installed on a carpeted area a solid surface wood metal or approved hearth pad must be installed between the unit and the carpet 6 This unit uses large quantities of air for comb...

Страница 15: ...hermostat Installation 1 Install the wall thermostat millivolt rated thermostat recommended or a 12 24 Volt rated thermostat set to millivolts in a location that is not to close too the unit but will...

Страница 16: ...llowable exterior vent termination locations Table 2 Use in conjunction with Figure 6 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above grass t...

Страница 17: ...ight homes and mobile homes When connecting to an outside fresh air source do not use plastic or combustible pipe A 3 minimum 76 mm ID inside diameter steel aluminum or copper pipe or ducting should b...

Страница 18: ...al Ensure the unit is electrically grounded to the chassis of your home permanently Do not install in a room people sleep in Outside fresh air is mandatory Secure outside air connections directly to f...

Страница 19: ...fastened with at least three 3 screws 1 Place the appliance 15 37 5 cm away from the wall If the stove will be installed a hearth pad set the unit on it 2 Locate the center of the exhaust pipe on the...

Страница 20: ...tallations have 3 to 5 feet 91 to 152 cm of vertical pipe in the system to help naturally draft the unit in the event of extreme weather or a power outage Some horizontal through wall installations ma...

Страница 21: ...Vertical section of vent pipe Horizontal frame for thimble 90o elbow Concrete Wall Clean out tee Installation to use if there is a concrete or retaining wall in line with exhaust vent on pellet stove...

Страница 22: ...stallations section and then finish it by performing the following refer to Figure 15 1 Install a tee with clean out on the outside of the house 2 Install PL vent upward from the tee Make sure that yo...

Страница 23: ...hen the pellet vent is installed vertically it will meet the minimum clearance from a combustible wall stated by the vent manufacturer 2 Install the tee with clean out 3 Install the pellet vent upward...

Страница 24: ...imney If holes already exist fresh air intake can be taken through back of the fireplace or through the ash dump Installation Hearth Mount Installation Figure 17 Hearth Mount Side View Figure 18 Heart...

Страница 25: ...d to attach the kit to the rear of the unit as shown Please see kit instruction manual for more detailed installation instructions The stove must also be connected to an existing 6 flue where permitte...

Страница 26: ...If the 3 light is flashing unit may be out of fuel Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT See section 8 The Fuel will not light Check the fuse on the circuit board If the unit still...

Страница 27: ...ire vertical section to move termination into a low pressure zone To reset Circuit Board after a trouble code push the ON OFF button 5 Unit is on but auger motor does not turn at all Check the line fu...

Страница 28: ...oing out If the stove goes out and leaves fresh unburned fuel in the burn pot liner the fire is going out before the stove shuts off Trim the combustion air down to decrease the magnahelic pressure Tu...

Страница 29: ...or Grey Grey Orange Orange White Grey Grey White Blue Yellow Auger Motor White Yellow Vacuum Switch Connect Thermostat Here Brown Brown Blue Purple Yellow Red Thermostat Combustion Blower Black Black...

Страница 30: ...ATE 50 2036 15 AGITATOR DRIVE BRACKET 50 2038 16 SS BURN POT LINER 50 2042 17 EXHAUST STARTER TUBE CW GASKET 50 2043 18 CAST FLUTED FIREBOX LINER 50 2048 19 HOPPER SWITCH 50 2052 20 EXHAUST MOTOR CAPA...

Страница 31: ...50 2114 37 M55C FS CAST LEG LIP RIGHT BEACH 50 2126 37 M55C FS CAST LEG LIP RIGHT CHESTNUT 50 2134 40 M55C FS CAST ASH DOOR 50 2115 38 M55C FS CAST ASH DOOR BEACH 50 2127 38 M55C FS CAST ASH DOOR CHES...

Страница 32: ...Parts Diagram Components 26 22 48 19 54 1 52 55 2 53 23 25 10 44 32 33 11 24 4 9 6 3 12 21 20 40 50 31 39 42 47 15 8 7 49 56 43 51 5 14 16 27 46 17 45 32...

Страница 33: ...33 Parts Diagram CAST 30 18 28 35 37 13 29 38 36 34...

Страница 34: ...Notes 34...

Страница 35: ...als for which the unit is not certified by the EPA and void if not operated according to the Owner s Manual Exclusions An expanded list of exclusions is available at www enviro com help warranty html...

Страница 36: ...L NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE _____________...

Отзывы: