23
Installation
T
YPICAL
T
HROUGH
W
ALL
W
ITH
E
XTERIOR
B
LOWER
K
IT
I
NSTALLATION
- H
ORIZONTAL
T
ERMINATION
:
���������� �����
�� �
��� �����
�������� ���� ������
������ �� ��������� �����
����������� ����
��� �����
���� �������
�������� ������
��� �������
���� �����
�� ������ ����� ��
��� ������� ������
Install an amour coated electrical cable from the exhaust blower housing, through the wall thimble plate
and attach to the pre drilled hole in the left hand rear hopper pillar. Hook up to wires from the exhaust
blower wiring harness.
All electrical connections must be in accordance to local code requirements
NOTE:
Ensure that all vent connections are installed by placing a small bead of high temperature silicone at each
chimney connection.
Also ensure that all vertical vent sections are properly supported and that all clearances to combustibles
are maintained in accordance with the vent manufacturer’s specifications.
Figure 23: Through Wall Installation with Exterior Blower Kit.
Figure 24: Through Wall Installation with Exterior Blower Kit; Side View.