Location of the Pellet Fire
Installation of the Enviro Classic Wood Pellet Burning Heater should be undertaken by an
experienced installer. Please read the Classic Owners/Technical Manual thoroughly before
commencing installation as failure to follow the instruction could cause damage to the pellet
fire or property.
Positioning the fire:
Generally the Classic should be installed in a centrally located position within the home. When
deciding where to position the appliance in your room you need to consider the following:
•
Location of a power source
•
The Classic has a convection fan which blows air through tubes in the direction that the
fire faces, for optimum performance this location should be in a large room centrally
located.
•
The Classic must be installed on a non-combustible surface. This surface must protrude
150mm from the front of the closed pellet fire door.
•
The Classic has been Safety Tested to AS/NZS 2918 using the Davins manufactured
flue. Test Report ARS 05/1185. Installation is not exclusive to these nominated kits,
though alternative flue should only be considered following consultation with your local
council.
•
Please consult page 3 for the required clearances to combustible material also ensure
the position of structural elements near the proposed flue.
•
Because of the positive pressure in the flue, sealing of all 75mm stainless joints is
mandatory – use high temperature sealant. Both inner and outer flue joints must be
riveted.
•
Seismic Restraint: Please see page 9 for requirements.
•
Warranty: To validate warranty following installation a copy of the completed Warranty
Registration Form/Producer’s Statement must be forwarded to: Switch - Fax (03) 341
8057.