4

November 2011

Location of the Pellet Fire

Installation  of  the  Enviro  Classic  Wood  Pellet  Burning  Heater  should  be  undertaken  by  an 

experienced  installer.  Please  read  the  Classic  Owners/Technical  Manual  thoroughly  before 

commencing installation as failure to follow the instruction could cause damage to the pellet 

fire or property. 

Positioning the fire:

Generally the Classic should be installed in a centrally located position within the home. When 

deciding where to position the appliance in your room you need to consider the following:

• 

Location of a power source

• 

The Classic has a convection fan which blows air through tubes in the direction that the 

fire faces, for optimum performance this location should be in a large room centrally 

located.

• 

The Classic must be installed on a non-combustible surface. This surface must protrude 

150mm from the front of the closed pellet fire door.

• 

The Classic has been Safety Tested to AS/NZS 2918 using the Davins manufactured 

flue. Test  Report ARS  05/1185.  Installation  is  not  exclusive  to  these  nominated  kits, 

though alternative flue should only be considered following consultation with your local 

council.

• 

Please consult page 3 for the required clearances to combustible material also ensure 

the position of structural elements near the proposed flue.

• 

Because  of  the  positive  pressure  in  the  flue,  sealing  of  all  75mm  stainless  joints  is 

mandatory – use high temperature sealant.  Both inner and outer flue joints must be 

riveted.

• 

Seismic Restraint:  Please see page 9 for requirements.

• 

Warranty:  To validate warranty following installation a copy of the completed Warranty 

Registration Form/Producer’s Statement must be forwarded to: Switch - Fax (03) 341 

8057.

Содержание EF2

Страница 1: ...ing Models Installation Specifications Safety testing of the EF2 Classic FS CB Pellet Burning Heater to AS NZS 2918 ARS 09 1981 08 1902 Emissions 07 1731 Safety testing of the EF2 Classic FPI CB Pelle...

Страница 2: ...2 November 2011 Installation Dimensions Classic Freestanding Dimensions Classic Insert Built In Heater 597 mm 525 mm 556 mm 767 mm FPI 612 mm 333 mm 559 mm FPI 579 mm...

Страница 3: ...H A E J J F B I F E Location Dimension mm A 100 B 150 C 50 D 210 E N A F 75 G 50 H 100 I 50 J 25 Location Dimension mm K 100 L 920 M 1020 N 150 O 150 P 50 NOTE Built In fire clearances don t apply in...

Страница 4: ...ted The Classic must be installed on a non combustible surface This surface must protrude 150mm from the front of the closed pellet fire door The Classic has been Safety Tested to AS NZS 2918 using th...

Страница 5: ...ing plate is white T he support angles for securing the liner to the ceilin g are not shown Kit is supplied in a carton Heat resistant floor protector Seismic restraint to be fitted 50mm minimum clear...

Страница 6: ...s supplied in a carton Note The Davin 51 External Standard Flue Kit complies with AS NZS 2918 2001 as per Applied Research Test Report 05 1185 dated 15 September 2005 All fires must be installed by a...

Страница 7: ...ies with AS NZS 2918 2001 as per Applied Research Test Report 05 1185 dated 15 September 2005 All fires must be installed by a qualified installer as per the manufacturer s instructions and AS NZS2918...

Страница 8: ...the flue is 3 6m Kit is supplied in a carton Note The Davin 54 Built in Heater Flue Kit non Chimney complies with AS NZS 2918 2001 as per Applied Research Test Report 05 1185 dated 15 September 2005 A...

Страница 9: ...HVU Installation of the Insert Model non combusitble cavity requires the use of a seismic restraint chains to be fitted one on each of the fire at the mid point The chain should have a breaking stren...

Отзывы: