Figure 20: Freestanding installation into mobile home.
Manufactured (Mobile) home installation must be in accordance with the Manufactured Home Construction
and Safety Standard, UL 307B, Title 24 CFR, Part 3280 and/or The Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A.
WARNING: DO NOT INSTALL IN SLEEPING ROOM.
Chimney must be removable to allow for
transportation of the mobile home.
CAUTION:
THE STRUCTURAL INTEGRITY
OF THE MOBILE HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.
OUTSIDE AIR :
Connection from the stoves air intake to the outside
is
mandatory
, (MOBILE HOMES ONLY) either
through a hole in the wall not higher than the stoves
bottom or through a hole in the floor, using the
fresh air adaptor. Avoid cutting any floor joists, wall
studs, electrical wiring or plumbing. Seal around the
outside air pipe with insulation to prevent drafts.
Also install a ¼” mesh rodent or pest screen in the
end of fresh-air pipe. Fresh-air connection must be
of a non-combustible material, example: 4” (10.16
cm) flexible aluminum single wall pipe.
Fresh air could also be supplied from a
vented
crawlspace.
The legs must be firmly bolted to the floor using
four ¼” bolts. Be sure to replace any insulation or
panels removed when fastening the bottom nuts.
If room air starvation occurs because the air intake
is blocked with ice, leaves etc., or because the stove
door was left open, or due to a strong exhaust fan
operating, dangerous fumes could be sucked into
the room.
IN SOME AREAS IT MAY BE REQUIRED TO
ELECTRICALLY GROUND THE STOVE TO THE STEEL
CHASSIS OF THE MOBILE HOME.
When this unit is installed in a Mobile Home it must
be grounded to the steel chassis or connected to a
grounding rod.
Installation
At least
3 feet (914 mm)
Hearthpad
Floor
Woodstove
Outside air connection
through wall or floor
Double wall pipe
Ceiling support
Ceiling
Spark arrestor cap
Roof flashing
Roof
Radiation Shield
Insulated
chimney
Bolt stove to floor
28