12. ROUTINE MAINTENANCE

Periodically check to ensure that the "B-Vent" venting 
system is clear and that a negative draft is present 
when the unit is operating. On fireplace insert models 
there is a  draft inspection tube the opening is located 
on the right hand side behind the hinged side. A 
vacuum should be present at the opening. 
 
Periodically check the pilot and burner flames (See 
Fig.11) 
 

CLEANING OF GLASS 
 

Do not clean glass when hot

 

 
It will be necessary to clean the ceramic glass 
periodically.  During a cold start up condensation will 
sometimes form on the glass, this is a normal 
condition with all gas fireplaces and stoves.  However, 
sometimes this condensation can allow dust and lint 
to cling to the glass surface.  Also, sometimes initial 
paint curing of the appliance can leave behind a slight 
film on the glass.  This is a temporary problem. It is 
therefore recommended that the glass be cleaned 
initially after about the first two weeks of use. 
 
After that, depending upon the amount of use, 
cleaning should be required no more than two or three 
times per season. 
 
To clean the door, use a mild glass cleaner and a soft 
cloth.  Abrasive cleaners will damage the glass 
surface. 

 
OPENING THE GLASS DOOR

 

 
Turn unit off and wait until the appliance has cooled 
down. 
 
1.  Open the right hand hinged side flap which will 
expose a door fastener.  Using a 1/2" wrench, loosen 
the fastener. 
 
2.  Due to the shape of the bay window door. You 
must also open the left hand side flap before 
attempting to open the door. 
 
3.  Ensure the door is properly fastened after cleaning 
before attempting to re-light the appliance. 

 

TO REPLACE DOOR AND GLASS ASSEMBLY 

The glass in this appliance is an integral part of the 
door assembly.  If the glass is damaged or broken a 

replacement door assembly including glass must 
be fitted. 

To Replace 

• 

open door fully 

• 

Lift door vertically so that hinge pins lift out 
of hinge receivers. 

• 

Return assembly to dealer.

 

The Door and glass assembly must be replaced as 
a complete unit by your ENVIROGAS Dealer.  No 
substitute materials are allowed

 

FOR CLEANING THE INSIDE OF THE 
FIREBOX 

 
Remove the log carefully from the firebox.  Gently 
remove the embers and place on a piece of paper 
towel. 
 
Vacuum the firebox thoroughly.  Carefully clean 
off any dust on the logs and remove any lint from 
the main burners and pilot burner. 
 
After carefully replacing the log and embers in 
their correct positions, and the door has been 
resealed, re-light the pilot, following the 
instructions on the attached label. 

 

CLEARANCES MUST BE SUFFICIENT TO ALLOW 
ACCESS FOR MAINTENANCE AND SERVICE 
 

LUBRICATING THE BLOWER 

Every 6 months the blower should be lubricated if 
installed

  

 
1.  Turn the unit off and remove the log set.  
 
2.  Remove the burner tray assembly by removing 
the screw on either side of the tray, between the 
front and rear burners.  Lift tray out. 
 
3. Remove the 8 screws that hold the blower 
mounting plate to the back firewall. 
 
4.  Carefully pull the blower assembly into the 
firebox, exposing the blower lubricating holes ( 
located on the top of the motor housing on either 
side of the label).  Add 2 drops of SAE 20 oil. 
 
5. If removal of the blower is necessary, 
disconnect the blower leads from the harness.  
Remove the blower. 
6.  To re-install, check mounting plate gasket and 
reverse steps 1 through 4. 

 

15

Содержание 828 BV. INS.

Страница 1: ...pliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Insta...

Страница 2: ...s installation must conform with local codes or in the absence of local codes with the current CAN CGA B149 installation code in Canada or the National Fuel Gas Code ANSI Z223 1 2 in the USA To prevent injury do not allow anyone who is unfamiliar with the operation to use the stove Always keep the area around these appliances clear of combustible material gasoline or other flammable vapors and liq...

Страница 3: ...r GAS FIRED VENTED ROOM HEATER in CANADA and the USA as follows ENVIROGAS 828 VENTED ROOM HEATER 828 BV FPI Nat LPG 828 BV FS Nat LPG TESTED TO ANSI Z21 11 1b 1993 CAN 1 2 1M 86 2 SPECIFICATIONS ENVIROGAS 828 VENTED ROOM HEATER This unit must be vented using certified B Vent venting has been certified for use with either natural or propane gases see rating label is not for use with solid fuels is ...

Страница 4: ...d system 3 DIMENSIONS AND CLEARANCES TO COMBUSTIBLES FIREPLACE INSERT CLEARANCES TO COMBUSTIBLES A Mantle pillar to stove 10 25 cm B Stove top to 8 wide mantle 12 31 cm Stove must sit on a non combustible surface the width and depth of the insert Maintain sufficient clearances for operation service and maintenance OTHER DIMENSIONS A Depth of unit into fireplace 11 28 5 cm B Depth of unit out of fi...

Страница 5: ...window or door that may be opened 12 inches 30cm minimum C Clearance to permanently closed window minimum 12 inches 30cm recommended to prevent condensation on window D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60cm from the center line of the terminal 24 inches 60cm minimum E Clearance to unventilated soffit 18 inches 45cm minimum F ...

Страница 6: ... damage is observed do not use unit and contact your local dealer 4 Remove the vent collar plate from the top of the stove by unscrewing the T20 Torx screw located on the center top of the stove and slide backwards SEE FIGURE 4 Properly secure the vent collar plate to the approved flexible pipe liner previously installed in the chimney Be careful not to over stretch the liner Figure 5 5 Place the ...

Страница 7: ...MBLING YOUR ENVIROGAS 828 FREESTANDING APPLIANCE 1 Open the two hinged side panels open the door 2 Remove log and ember set and all wrapping material from the stove Check for damage If damage is observed do not use unit and contact your local dealer 3 Remove the two wood screws that secure the stove to the pallet these are located through the square openings inside the side panels 4 Place the stov...

Страница 8: ...Efficiency and heat output of the unit increases with the operation of the fan This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong outlet DO NOT cut or remove the grounding prong from this plug The appliance when installed with optional blower must be electrically connected and gro...

Страница 9: ...ure tests ORIFICE SIZES PRESSURES AND BTU S The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system All models are equipped with a variable output gas control NATURAL GAS PROPANE ORIFICES Front Rear 51 DMS 49 DMS 59 DMS 56 DMS Manifold Press 3 5 wc 0 87 kPa 10 0 wc 2 49 ...

Страница 10: ... or stainless steel flex vent and or certified 4 Type B Gas Vent The flue collar of the appliance will fit inside of a standard 4 vent and may be fastened directly to the vent Check periodically that the vent is unrestricted and an adequate draft is present when the unit is in operation WARNING Operation of this heater when not connected to a properly installed and maintained venting system or tam...

Страница 11: ...This stove should be vented by certified 4 Type B Gas Vent that may be encased in 6 decorative stovepipe The flue collar of the appliance will fit inside of standard vent and should be fastened directly to the vent The ENVIROGAS incorporates its own internal draft hood so no additional external draft hood is required The venting system should be assembled and installed according to the vent manufa...

Страница 12: ...should be a minimum of 3 ft 62m from the top of the unit before any horizontal For other special venting requirements please refer to the local state provincial or national codes The bottom of the vent cap shall extend at least 2ft 6m above the highest point of the roof where it passes through and at least 2ft 6m higher than any portion of the roof within a horizontal distance of 10ft 3m See Figur...

Страница 13: ...a single row of embers on top of the front burner Figure 16 Figure 16 2 Carefully avoid any clumping or large build ups Do not pack down leave embers loose 3 DO NOT PLACE EMBERS ON THE REAR BURNER 4 Upon the first light up watch for ignition to all burner ports If a long delay is noted a First wait for the appliance to cool down b Open the front door of the appliance c Carefully reposition the emb...

Страница 14: ...trol knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out any gas Close door If you smell gas including near the floor STOP Follow B in the above safety information If you don t smell gas go to next step 5 Find the pilot located to the right between the front and rear burner 6 Turn gas control knob counter clockwise to PILOT 7 Push the gas control knob in fully and hold ...

Страница 15: ...fter cleaning before attempting to re light the appliance TO REPLACE DOOR AND GLASS ASSEMBLY The glass in this appliance is an integral part of the door assembly If the glass is damaged or broken a replacement door assembly including glass must be fitted To Replace open door fully Lift door vertically so that hinge pins lift out of hinge receivers Return assembly to dealer The Door and glass assem...

Страница 16: ...ck gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pressure Check for flame impingement on thermopile if low see Pilot will not stay lit check thermopile for a Minimum of 300 mV when burner switched on Check wiring to thermostat for breaks Check for spillage at draft hood that may trip spill switch Flame lifting Leak in vent pipe Improper...

Страница 17: ...44 Nova Pilot W Ignitor Electrode LP 828 030 Log Set Embers 828 045 3 8 Plastic Bushing 828 046 7 8 Plastic Bushing 828 054 Hi Temperature Electrical Cord 828 072 3 8 Tadpole Door Gasket 828 076 Envirogas Name Plate 828 077 120 Ceramic Auto Reset n o Temp Sensor big foot 828 078 220 Temp Sensor n c 828 079 SS Flex Connector with 3 8 Elbow 18 long 828 081 Fan Switch Plug 828 083 Freestanding Side C...

Страница 18: ...nst flaking This offer includes parts and labor for 1 year and for parts only thereafter Your dealer shall make all claims under this warranty in writing A TO A MAXIMUM OF SEVEN YEARS WHEN FILING A WARRANTY CLAIM PLEASE COMPLETE THE FOLLOWING INFORMATION ON AN OFFICIAL WARRANTY CLAIM FORM To the Dealer Name address and telephone number of purchaser and date of purchase Date of installation Name of...

Страница 19: ...___________ Name of Installer ___________________________________________ Address ___________________________________________ ___________________________________________ ___________________________________________ Phone _____________________________________ Model ___________________________________ Serial Number __________________ Date of Purchase __________ ________ ________ Date of Installation ...

Страница 20: ...20 ...

Отзывы: