8. VENTING
WARNING:
THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR AND
DILUTION AIR FROM THE ROOM. IT IS ALSO DESIGNED TO DRAW ROOM AIR FOR PROPER HEAT
CIRCULATION FROM THE SIDES OF THE UNIT. BLOCKING OR MODIFYING THE LOUVERS IN ANY WAY CAN
CREATE HAZARDOUS SITUATIONS, EITHER THROUGH POOR VENTING OR BY OVERHEATING. IT IS
IMPORTANT THAT THIS UNIT HAS SUFFICIENT AIR CIRCULATION FOR PROPER VENTING AND
COMBUSTION. PROVISIONS MUST BE MADE FOR THE SUPPLY OF ADEQUATE COMBUSTION AND
VENTILATION AIR. THESE OPENINGS MUST NOT BE BLOCKED.
THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVICING
A SEPARATE SOLID FUEL BURNING APPLIANCE.
AUTOMATIC FLUE GAS SPILL SWITCH
NOTE: THIS HEATER MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM. THIS HEATER IS EQUIPPED
WITH A VENT SAFETY SHUTOFF SYSTEM DESIGNED TO PROTECT AGAINST IMPROPER VENTING OF
COMBUSTION PRODUCTS.
THIS SAFETY SWITCH IS LOCATED ON THE REAR OF THE APPLIANCE CLOSE TO
THE DRAFT HOOD RELIEF OPENING.
IF THE SWITCH TRIPS MORE THAN ONCE THE VENTING SHOULD BE INSPECTED BY A QUALIFIED
SERVICE TECHNICIAN FOR POSSIBLE BLOCKAGE OR SEVERE DOWN DRAFT CONDITIONS
This stove can be vented with aluminum or stainless steel flex vent and/or certified 4" Type B Gas Vent. The
flue collar of the appliance will fit inside of a standard 4” vent and may be fastened directly to the vent.
Check periodically that the vent is unrestricted and an adequate draft is present when the unit is in operation.
WARNING:
Operation of this heater when not connected to a properly installed and maintained venting system
or tampering with the vent safety shutoff system can result in carbon monoxide (CO) poisoning and possible
death.
A. VENTING FIREPLACE INSERTS
The ENVIROGAS 828 insert may be installed and vented into
any solid fuel fireplace that has been installed in accordance
with the National, Provincial/State and local building codes and
has been constructed of non-combustible materials.
An approved 4" chimney liner, throat connector, and rain cap
must be installed, to ensure a tight seal, top performance,
safety
and efficiency. Carefully follow the manufacturers instructions
which accompany the chimney liner kit.
Measure the height of the chimney beforehand and purchase
the appropriate kit.
Never attempt to over stretch a flexible
liner to accommodate the height of the chimney.
Install sealed throat connector to prevent leakage of room air
through chimney.
Any flue damper must be removed or blocked permanently in
the open position.
The chimney must be clean, in good working order and
10