The Horizontal Vent Kit (50-3664) must be used in conjunction with the Q1 Co-linear Vent Kit (50-

2982) and ensure that the unit air restrictors are set to fully open as this venting kit functions best 

without any restriction. See owner’s manual for more information. See Owner’s Manual for installa-

tion.

This kit is NOT compatible with the Q1 fireplace configuration.

The kit is directly compatible with any E series unit.

Compatible Models:

Q1 G

eneral

 I

nformatIon

Initial Installation

Step 1:

Remove the Horizontal Vent Kit from the packaging. Ensure there is no damage to the vent piping or 

termination cap. If there is damage contact your dealer, distributor, or courier company before start-

ing this installation.

I

nstallatIon

:

IMPORTANT: If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1.5 

inch (37.5 mm) or less may be drilled through the lower sides or bottom of the firebox in a proper 

workmanship like manner. This access hole must be plugged with non-combustible insulation after 

the gas supply line has been installed. Cutting any sheet-metal parts of the fireplace, in which the gas 

fireplace insert is to be installed is prohibited. The label plate shown on the right, included with co-

linear venting adapter kit, must be permanently attached inside the cavity of the fireplace in a visible 

location.

Note: Space must be left for gas line on left side of unit for servicing purposes

Install Information:
The flue damper must be fully blocked open or removed for installation of the unit; the smoke 

shelves, shields and baffles may be removed if attached by mechanical fasteners. 
The fireplace and fireplace chimney must be clean, in good working order and constructed of non-

combustible materials.
Make sure that all chimney cleanouts are tight fitting and will not permit air to leak into the chimney.
Refractory, glass doors, screen rails, screen mesh and log grates can be removed from the fireplace 

before installing the unit.
Install a sealed vent cap to prevent leakage of room air up through chimney.
The intake and the exhaust are 3” (76mm).
Ensure that the fireplace and chimney have been thoroughly cleaned prior to install.

50-3664 Installation

QUALIFIED INSTALLERS ONLY

Not Compatible Models:

•  Q1C

•  Q1CI

•  Q1L

•  Q1LI

•  Q1G

•  Q1GI

•  E30L

•  E30LI

•  E30G

•  E30GI

•  E33L

•  E33LI

•  E33G

•  E33GI

•  EX32

•  EX35

a

ll

 I

nserts

 G

eneral

 I

nformatIon

Содержание 50-3664

Страница 1: ...et metal parts of the fireplace in which the gas fireplace insert is to be installed is prohibited The label plate shown on the right included with co linear venting adapter kit must be permanently attached inside the cavity of the fireplace in a visible location Note Space must be left for gas line on left side of unit for servicing purposes Install Information The flue damper must be fully block...

Страница 2: ...T TH 10 4 2018 Roughly 6 3 4 Roughly 5 3 4 NOTE Holes are orientated at a 40 degree angle Roughly 5 3 Dia 4 Dia Exterior View Exhaust Intake Step 4 Prebend the intake and exhaust venting do NOT ex ceed 90 degrees After the elbow stretch the venting to the desired vertical height Step 5 Attach the venting to the wall terminal using the sup plied hose clamps Note the exhaust inlet is the inlet with ...

Страница 3: ...ar of the fireplace for the Q1 C 15600 Initial Installation QUALIFIED INSTALLERS ONLY Figure 3 Venting Minimum and Maximum Step 8 Attach the venting to the top of the fireplace using 3 screws per vent Making sure the intake is on the intake collar The intake collar is on the left side of the fireplace for the Q1 and is indicated on the flue collar of the E series units by the IN Step 9 Proceed wit...

Страница 4: ...us les nettoyeurs de cheminée sont bien ajustés et ne permettront pas à l air de s infiltrer dans la cheminée Les réfractaires les portes en verre les glissières les grilles et les grilles peuvent être retirés du foyer avant l installation de l appareil Installez un capuchon d évent hermétique pour empêcher toute fuite d air de la pièce par la chemi née L entrée et l échappement sont de 76 mm 3 po...

Страница 5: ...BE COPIED REPRODUCED OR OTHERWISE DISCLOSED WITHOUT THE 10 4 2018 Grossièrement 6 3 4 Grossière ment 5 3 4 Remarque Les trous sont orientés à un angle de 40 degrés Grossièrement 5 3 Dia 4 Dia Vue extérieure Échappement Admission Étape 4 Prébender les entrées et sorties d air NE PAS dépasser 90 degrés Après le coude étirer la ventilation à la hauteur verticale souhaitée Étape 5 Fixez la ventilation...

Страница 6: ...le Q1 et est indiqué sur le collet de cheminée des appareils de la série E par IN Étape 9 Procédez à l installation régulière pour le modèle donné La hauteur verticale minimale est mesurée à partir de la ligne centrale du collet d admission La hauteur verticale maximale est mesurée à partir de l axe du collet d échappement 5 maxi mum pour les installations Q1 Remarque le col lier d admission est p...

Отзывы: