Пользовательский мануал Envionic FA720 доступен для загрузки совершенно бесплатно на нашем сайте. Этот мануал поможет вам ознакомиться с функционалом устройства и использовать его на полную мощность. Скачайте его прямо сейчас на manualshive.com.
Users manual
FA845
version 1.5
Envionic
1
Field Analyzer FA845
Users Manual
Also for the FA720, FA725, FA730 and FA735
www.envionic.com
Страница 1: ...Users manual FA845 version 1 5 Envionic 1 Field Analyzer FA845 Users Manual Also for the FA720 FA725 FA730 and FA735 www envionic com...
Страница 2: ...hapter 3 RF SCAN mode 21 3 1 Spectrum analyzer introduction 21 3 2 SCAN Display 22 3 3 SCAN Frequency bands 23 3 4 SCAN Peak display 24 3 5 Other functions in SCAN mode 25 3 6 Single frequency measure...
Страница 3: ...1 5 Envionic 3 7 3 View measurements with your computer 45 Appendices 46 Appendix 1 Specifications FA845 46 Appendix 2 Conversion from microwatt m to milliVolt meter 47 Appendix 3 More information 48...
Страница 4: ...me mode you can view these pulses on the screen The spectrum analyzer can measure very low field strengths and their frequency The figures measured are displayed on a clear graphic LCD display The low...
Страница 5: ...WLAN or WIFI wireless computer networks WIMAX wireless network wireless video systems microwave ovens bluetooth wireless systems television transmitters 2 Low frequency electric fields FA 730 735 845...
Страница 6: ...card to the USB port of your computer The memory card and cardreader are only delivered with the FA725 FA735 and FA845 Two AA Alkaline batteries or optional two NiMH rechargeable batteries Optional ch...
Страница 7: ...screen as long as the device is switched on On the screen you will see the model number FA845 FA735 FA730 FA725 or FA720 software version Image V 2 0 and serial number 0504 of the device This manual...
Страница 8: ...should only be placed or removed when the device is switched off The card should be placed with its contacts pointing upwards to the top of the device You can use your nail to push it the last stretch...
Страница 9: ...n choose what you want to measure Push the 1st button RF to measure the high frequency electromagnetic field chapter 2 Push the 2nd button Elec to measure the low frequency electric field chapter 5 Pu...
Страница 10: ...After some practice it is possible to identify the kind of radiation by the sound it produces The strength of the radiation has not much influence on the sound volume unless the signals are very weak...
Страница 11: ...n the screen At first as a partly filled battery see picture After some time the filling in the battery picture will blink When the battery can no longer be used an empty battery symbol will blink Aft...
Страница 12: ...ies are being charged then switch the device on You will see an animated picture of a battery that that is being filled Then you can switch the device off again If you keep the meter on while the batt...
Страница 13: ...on becomes available it can be sent to you by email The following steps must be followed to install new software 1 Switch your device OFF and remove the memory card 2 Put your memory card in the cardr...
Страница 14: ...lected by big objects indoor or outdoor objects The combination of direct and reflected signals causes interference patterns Due to interference the measured value can vary a lot even when the device...
Страница 15: ...enuated while travelling through your body Most signals have a vertical polarization Due to this a vertical position of the device and antenna is optimal when using the non directional antenna Signals...
Страница 16: ...trength of the signal in microwatt per square meter When the signal is pulsed the shown strength is the strength at the top of the pulse The frequency of all signals is measured if possible and the fr...
Страница 17: ...you can also see small signals while strong pulses of another frequency are present Above the signal with the highest strength you will see a small arrow and the corresponding frequency category is vi...
Страница 18: ...Choosing the measurement unit Within the Hold function group you will als find the Unit button button 2 Here you can change the measurement unit of the device you can choose between microwatt per squa...
Страница 19: ...will now see Time instead of GHz Pressing button 2 again it is now called Freq will switch back to the normal display The following example shows the pulses of a DECT base station The dotted line is t...
Страница 20: ...g sleep according to the German SBM2015 standard Also the values with qualification slight concern severe concern and extreme concern will be visible This only works in the microwatt per square meter...
Страница 21: ...een given two major operating modes 1 SCAN described in this chapter In the SCAN mode the user selects the frequency band that he wants to measure It is selected from a fixed list of bands The START a...
Страница 22: ...nd Stop frequencies 925 and 960 MHz for GSM900 D The dotted line shows the position of the strongest signal E Indicates that button 3 selects the previous frequency band F Indicates that button 6 sele...
Страница 23: ...nd is shown as an arrow pointing upwards EU means that this is a frequency band used in Europe in the USA and some other countries the band frequencies are slightly different In the described software...
Страница 24: ...1 5 Envionic 24 3 4 SCAN Peak display A dotted line D will show the position of the strongest signal called Peak The frequency of the strongest signal is shown at the left side of the screen B and th...
Страница 25: ...see next section B The marker function lets you control the dotted line by using left and right buttons The frequency at the marker position is shown at the left side of the screen and the strength a...
Страница 26: ...es strongly every second in SNGL mode this means that this is a mirror image frequency A mirror image frequency is an unwanted signal that is not really present at the specified frequency The device a...
Страница 27: ...in the next diagram where the antenna has been disconnected to remove the signal You see that the display shows 00001 the actual level with disconnected antenna If you select HOLD and switch it from o...
Страница 28: ...fter the last frequency band the file must end with with The description will be shown on the screen of the device as 3 rows of maximal 4 characters When a row starts with U or D followed by a space t...
Страница 29: ...and list file select it from the Home screen by selecting Menu and then Card Then select the xxxxxxx ini file and press Open This will load the file in the device This must be done each time after swi...
Страница 30: ...N mode to EXPERT mode select Disp with button 4 and then use button 2 Xprt 4 1 XPRT Display In the XPRT mode you will see the following screen At the left side of the screen there is no band informati...
Страница 31: ...the center frequency up or down in half SPAN steps using left and right buttons Button 1 Select CF center freq mode or PK peak freq mode Button 2 Set CF to PK frequency C MKR Move the dotted line mark...
Страница 32: ...F B will switch back to the first intermediate frequency A real signal will be visible at the same frequency for both values of the intermediate frequency But a mirror image will only be visible at on...
Страница 33: ...P 900 The CF center frequency has changed from 700 to 800 MHz The frequencies in the picture do not match this example In FREQ and SPAN modes you can use button 1 to toggle the indication between Peak...
Страница 34: ...the following screen The first 3 buttons can be used to enter the digits that are in a box 1 2 or 3 here A The backarrow removes the last entered digit B The up down buttons move the row of boxes up o...
Страница 35: ...CF center frequency will stay the same Example Suppose START 600 STOP 800 so SPAN 200 If you decrease the SPAN from 200 to 100 MHz you will get START 650 STOP 750 so SPAN 100 The center frequency 700...
Страница 36: ...ress button 1 and keep it pressed during one second this gives you the following screen Now pressing Num will let you enter the From START frequency After entering the start frequency press button 1 a...
Страница 37: ...uch too low The device should be grounded by placing one of your fingers at the grounding point at the backside of the device Grounding point The device responds to changes in the surrounding electric...
Страница 38: ...adjusted for optimal visibility The range is 0 5 V m up to 199 V m After switching the device on it will take 20 seconds before the electric field can be measured If you choose Hold switch this on as...
Страница 39: ...to the normal display For indoor living or working areas you can use values that are 10 times higher than the values during sleep that are shown here 5 4 Orientation for older devices In older devices...
Страница 40: ...everal position because it is only sensitive to a single direction of the magnetic field lines The highest measured value should be used The device should not be moved during the measurement Magnetic...
Страница 41: ...e Safe you will see together with the measured value what values are safe for the magnetic field strength during sleep according to the German SBM2015 standard Also the values with qualification sligh...
Страница 42: ...ent day Measurements of one day In the top line you see the year month date and the day of the week Choose the kind of measurements that you want to see with button 6 for instance RF uW m The logged R...
Страница 43: ...lue 160 The starting time of the chosen time period is shown at the top left corner of the screen in the example october 22 12 00 The frequency category that belongs to the choosen time period is at t...
Страница 44: ...upwards It will fit in two ways but it will work in only one way As soon as the cardreader is attached to the PC a window will pop up Choose Open folder to view files Then choose the folder Log and t...
Страница 45: ...rows Cell G10 up to R10 indicate the frequency category of the cells below them In this example several columns are deleted between column H and I to get a clearer picture The first frequency categor...
Страница 46: ...f pulsed signals Hold function for remembering the highest peak value SMA connector for external antenna Antenna for 700 MHz 6 GHz is included Low frequency Low frequency electric field from 0 5 V m u...
Страница 47: ...00 2 500 900 2 000 800 1 600 700 1 250 620 1 000 560 800 500 630 450 500 400 400 350 320 320 250 280 200 250 160 220 125 200 100 180 80 160 63 140 50 125 40 110 32 100 25 90 20 80 16 70 12 5 62 10 0 5...
Страница 48: ...potential difference mV milliVolt 0 001 Volt W Watt Unit for power energy per second W microWatt 0 000001 Watt DECT Digital Enhanced Cordless Telephone GSM Global System for Mobile Communications TET...