![envea STACK 602 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/envea/stack-602/stack-602_user-manual_2415516049.webp)
STACK 602
9 Maintenance
ENVEA
UK Ltd
(PC-000848-MA Issue 5, December 2021)
vii
9.
Maintenance
9.1
Safety Information
CAUTION!
Refer all servicing or maintenance to qualified service personnel.
WARNING!
–
HAZARDOUS VOLTAGES
This equipment contains lethal voltages!
Always switch OFF and isolate the unit from the power supply before
removing the front cover.
WARNING!
–
HAZARDOUS VOLTAGES
Hazardous voltages are still present when the main power supply
fuse has failed.
CAUTION!
Non-metallic parts may be cleaned with a dry or lightly dampened
cloth only. Do not use solvents or abrasives as these may damage
the surfaces. For sensor parts, follow the advice given in the
instructions.
9.2
Maintenance Mode
Maintenance mode allows sensors to be disabled for routine maintenance. There
are three ways of disabling a sensor:
Power OFF the control unit
: this removes power from all sensors in the
net
work. A ‘Power Interruption’ alarm will be recorded in the Event log
indicating the maintenance period. A gap will appear in the emission logs.
Disconnect the sensor from the network
: if the sensors are connected
into the network using spurs, it is possible to physically disconnect the
sensor from the network without affecting polling to the other sensors. A ‘No
Response’
alarm will be generated in the control unit for that channel during
the maintenance period.
Maintenance mode menu in the control unit
: sensors placed in
Maintenance mode will be re-enabled automatically after eight hours.
Содержание STACK 602