OPERATING & MAINTENANCE 

MANUAL 

 

 

 

 

EcoChem 

Recirculating Fume Cupboard 

Содержание ecoChem

Страница 1: ...gland Company Registration Number 10729379 VAT Registration Number 268 3290 80 P0084EN Rev 03 www envairlab co uk 44 0 1706 228416 info envairlab co uk OPERATING MAINTENANCE MANUAL EcoChem Recirculati...

Страница 2: ...NATED MATERIALS 19 5D ERGONOMICS 19 6 LIMITATIONS 20 7 OPERATING PROCEDURES 21 7A GENERAL OPERATING INSTRUCTIONS 21 7B FUME CUPBOARD SWITCHING ON 21 7C FUME CUPBOARD SWITCHING OFF 21 8 MAINTENANCE 23...

Страница 3: ...T Registration Number 268 3290 80 P0084EN Rev 03 www envairlab co uk 44 0 1706 228416 info envairlab co uk 14B FRONT DIAGRAM 38 14C SIDE DIAGRAM 39 15 ASSEMBLY DIAGRAM FOR SUPPORT TABLE 40 16 SENSORS...

Страница 4: ...gy Sterilization of endoscopes Ria test Manipulation of radioactive labelled compounds Assembly of medical devices The performances of the cabinets are detailed in the TESTING CERTIFICATE below in com...

Страница 5: ...228416 info envairlab co uk ENVAIR Lab LTD disclaims any responsibilities for malfunctions damages to people or properties due to non compliance omitted or poor maintenance and improper use of the equ...

Страница 6: ...nstallation the unit shall be protected from draughts and heat sources radiators fan convectors in order to create the best working conditions The clearance around the work opening shall measure at le...

Страница 7: ...aximum power upstream on the power input line The switch shall be fitted with a differential relay with operating current rate not exceeding 30 mA Any instrument with a heat source shall be located at...

Страница 8: ...1738x660x600 Maximum front aperture mm 455 455 455 455 455 Working aperture mm 200 200 200 200 200 Weigh Kg 70 85 100 115 130 Noise level dB A 52 52 52 52 52 Lighting level Lux 1000 1000 1000 1000 100...

Страница 9: ...ed at work surface level and is carried upwards into the upper part or head of the fume cupboard with an air flow inside the fume cupboard head air goes through a prefilter which cleans the air from p...

Страница 10: ...whose nature structure and chemical formula are unknown 4B SYSTEM AND PERFORMANCE CONTROLS The fume cupboards ECOCHEM are fitted with regulator in order to keep the airflow speed constant with the pro...

Страница 11: ...o obtain a 12 Vdc output to connect a LED light or alternatively a Normally Open voltage free contact to be connected to an external circuit This signal can be set in three different modes Motor ON Th...

Страница 12: ...the data stored in the microprocessor by pressing the Right Arrows key 9 10 Position ON Press the key ON 1 insert the password using the small numbers in the right lower corner of the keys and press S...

Страница 13: ...he minimum and maximum set limits 7 ESC ESC key deletes the operation of data input and goes back to the starting condition When an alarm condition occurs which is shown also by the message appearing...

Страница 14: ...The LCD will display for example WORK TIME XXXXXh This value cannot be reset 11 ALARM When an alarm occurs the red LED lights up 12 LIGHT This switches on the fluorescent light when enabled the displa...

Страница 15: ...CLOCK and the TIMER OPERATOR MENU Filter residual time OPERATOR MENU Language OPERATOR MENU Set up the clock OPERATOR MENU Change Password OPERATOR MENU History view OPERATOR MENU UV resid time STAND...

Страница 16: ...Use the up and down arrow keys to adjust the hour s parameter Then press the SET key 8 to confirm the data and pass to filter 2 and so on up to filter 5 as for relation between number and type of fil...

Страница 17: ...ESC 7 key PASSWORD CHANGE use UP DOWN arrow keys 5 6 to choose the desired menu select PASSWORD CHANGE and press SET 8 key the display will show CURRENT PSW digit the present Password then press SET k...

Страница 18: ...ress ESC to abort the procedure When the set time is reached the buzzer start to ring and the display show this message ALARM CLOCK ALARM Press the ESC key to silence the acoustic signal TIMER SET UP...

Страница 19: ...tched ON and stop when the ventilation is turned OFF It is possible RESET the hour counter pressing in sequence the following keys ESC Arrow down Arrow up SET After this the display will show this mes...

Страница 20: ...UTSIDE THE EUROPEAN UNION This symbol is valid only in the European Union If you want to dispose this product contact your local authorities or dealer and ask for the correct method of disposal ATTENT...

Страница 21: ...ume cupboard for manipulations operations if the activated charcoal filter installed is not adequate DO NOT use the fume cupboard if the pre filter is clogged and or the activated charcoal filter is s...

Страница 22: ...e of reagents bottles or when low toxicity compounds are handled We recommend to replace the pre filter each time you replace the activated charcoal filter A spare filter should always be kept availab...

Страница 23: ...any Registration Number 10729379 VAT Registration Number 268 3290 80 P0084EN Rev 03 www envairlab co uk 44 0 1706 228416 info envairlab co uk 4 Press I 0 key switch and enter the password for switchin...

Страница 24: ...removal of the contaminant Their use with saturated activated charcoal filter s implies the non removal of the contaminant With ECOCHEM M fume cupboards the microprocessor monitors the airflow speed...

Страница 25: ...lace 6 ml of the selected solvent into a beaker with a hotplate let it boil for two minutes This operation gives a solvent concentration equal to 100 200ppm Sample the outlet airstream from the unit f...

Страница 26: ...ith the correct bracket 3 located on the right side of the panel Raise the activated charcoal filters 4 by unscrewing the correct knobs 5 for a few centimetres Remove the activated charcoal filter 4 f...

Страница 27: ...Install the new motor fan 9 and fix it with the correct screws and washers 10 Reconnect the electric connectors to the terminal board of the new motor fan 9 Close the control panel 1 and fix it with t...

Страница 28: ...31100 upper front glass ECOCHEM 90 1 K60008531100 upper front glass ECOCHEM 120 1 K60008631100 upper front glass ECOCHEM 150 1 K60008731100 upper front glass ECOCHEM 180 1 K60008331200 lower front gla...

Страница 29: ...070A 10 06 net filter 1 1 1 1 1 V30000000030 SP 31 gas sensor only ECOCHEM M 1 1 1 1 1 V30000000090 Proximity NAMUR AEG 8 2 only ECOCHEM M 1 1 1 1 1 V30000008150 Microprocessor control card only ECOCH...

Страница 30: ...14 4 kg FX0000844050 CYAN filter for ECOCHEM 90 150 1 180 10 0 kg FX0000844060 MER filter for ECOCHEM 90 150 1 180 10 0 kg FX0000844070 ACR filter for ECOCHEM 90 150 1 180 10 5 kg FX0000844080 FOR fil...

Страница 31: ...harcoal by Van der Waals forces 2 ACR FILTER This filter is impregnated with halide salts and is used for the high efficiency removal of iodine and methyl iodine It is frequently used for iodination r...

Страница 32: ...0084EN Rev 03 www envairlab co uk 44 0 1706 228416 info envairlab co uk Mercury FX0000834860 450x300x30 60 FX0000854860 610x610x30 90 120 150 180 Urines FX0000834810 450x300x30 60 FX0000854810 610x610...

Страница 33: ...the cupboard GAS DETECTOR alarm for ECOCHEM M The charcoal filter is completely saturated Gas sensor broken if you are not working under the cupboard Replace the activated charcoal filter Replace the...

Страница 34: ...de or on the back panel By means of a forklift put the cabinet on a pallet to ensure good conditions of stability and to prevent the spill tray in the lower part of the fume cupboard from damages for...

Страница 35: ...128 cm 1cm thick ECOCHEM 150 202 x 90 x 128 cm 1cm thick ECOCHEM 180 202 x 90 x 128 cm 1cm thick Steel strap and clips During transport pay attention to maintain the package in vertical position i e...

Страница 36: ...per use of the fume cupboard by user also several contra indications in the instruction manual among which the following are reminded installation in a place not conforming to instructions wrong feed...

Страница 37: ...airlab co uk 44 0 1706 228416 info envairlab co uk 14 DRAWINGS AND DIAGRAMS LEGEND 1 Control panel 2 Fastening socket head screws 3 Bracket 4 Charcoal filter 5 Knobs 6 Pre filter case 7 Control box 8...

Страница 38: ...egistered in England Company Registration Number 10729379 VAT Registration Number 268 3290 80 P0084EN Rev 03 www envairlab co uk 44 0 1706 228416 info envairlab co uk 14A MAINTENANCE OPERATIONS DIAGRA...

Страница 39: ...Registered in England Company Registration Number 10729379 VAT Registration Number 268 3290 80 P0084EN Rev 03 www envairlab co uk 44 0 1706 228416 info envairlab co uk 14B FRONT DIAGRAM 14C...

Страница 40: ...Registered in England Company Registration Number 10729379 VAT Registration Number 268 3290 80 P0084EN Rev 03 www envairlab co uk 44 0 1706 228416 info envairlab co uk SIDE DIAGRAM 15...

Страница 41: ...Number 10729379 VAT Registration Number 268 3290 80 P0084EN Rev 03 www envairlab co uk 44 0 1706 228416 info envairlab co uk ASSEMBLY DIAGRAM FOR SUPPORT TABLE The supporting stand is supplied not ass...

Страница 42: ...10729379 VAT Registration Number 268 3290 80 P0084EN Rev 03 www envairlab co uk 44 0 1706 228416 info envairlab co uk The 4 stand brackets must be installed as follow 1 bracket with hole in the left f...

Страница 43: ...and Company Registration Number 10729379 VAT Registration Number 268 3290 80 P0084EN Rev 03 www envairlab co uk 44 0 1706 228416 info envairlab co uk The other 2 brackets left back leg and right front...

Страница 44: ...envairlab co uk 44 0 1706 228416 info envairlab co uk 16 SENSORS LIST PCB PLUG SOFTWARE NAME OF THE SENSOR DESCRIPTION PLUG Software name Description J9 CPULAF GAS SENSOR J4 CPULAF S0 Air flow sensor...

Страница 45: ...Registered in England Company Registration Number 10729379 VAT Registration Number 268 3290 80 P0084EN Rev 03 www envairlab co uk 44 0 1706 228416 info envairlab co uk 17 WIRING DIAGRAMS...

Страница 46: ...Registered in England Company Registration Number 10729379 VAT Registration Number 268 3290 80 P0084EN Rev 03 www envairlab co uk 44 0 1706 228416 info envairlab co uk...

Страница 47: ...Council on the approximation of the laws of the Member States relating to electromagnetic compatibility 2014 35 UE Directive of the European Parliament and of the Council on the harmonisation of the l...