User Manual
70405 ODE Mk2/
70406 ODE PoE Mk2
For the latest version visit:
www.enttec.com
December 2020
ID: 3275345
Page|1
Open DMX Ethernet Mk2
RDM compliant DMX over Ethernet Gateway
Box Contents
ODE Mk2 (SKU: 70405 or 70406)
Straight connect Ethernet lead (PN: 79102)
Power adapter if you have the POE option, the
power adapter is not included.
This user manual
Features
1 Universe Ethernet to DMX node (Output mode)
1 Universe DMX to Ethernet (Input mode)
Easy to setup & update through any web browser
Supports following DMX over Ethernet protocols:
o
Art-Net
o
Streaming ACN (sACN)
o
ESP
Supports RDM over Art-Net (controller)
Supports Art-Net 3
HTP/LTP Merging support: up-to 2 DMX sources
can be merged (if enabled).
1 RJ45 connector (10/100 Mbps)
Static or Dynamic (DHCP) IP configuration (DHCP by
default)
Supports IEEE 802.3af PoE (Power over Ethernet)
over RJ45 connector (
only on PoE model SKU 70406
)
Supports Art-Net Broadcast or Unicast (Input mode)
5Pin DMX XLR connectors
Safety
Do not expose the ODE Mk2 to rain or moisture,
doing this will void its warranty.
This unit is intended for indoor use only
Basic Setup
Right out of the box, the ODE Mk2 is factory configured to be
a DMX OUTPUT device, listening to the first Art-Net Universe
(0x00). It is also set as a
DHCP node
, so you can plug it into
your existing router, and it's good to go.
To make any changes to the configuration, you will need the
IP address of ODE Mk2.
If you connect ODE to a network router, it will be assigned
an IP address as per the router’s DHCP addressing. However,
if you connect ODE to a switch or a computer, it will use the
factory set static IP address (printed on the box).