DMX USB PRO MK2 (70314)
Visit the ENTTEC website for the latest version.
..
USER MANUAL
5
|
ID: 134658
Document Updated: Dec 2021
Config
Config tab allows the adjustment of DMX output parameters to accommodate for equipment that fall outside of the
USITT DMX512-A standard.
Following controls are available:
Set Parameters to Default: Selecting this will reset value
on both Port 1 & Port 2 to default value. Confirm update
by clicking on “Set DMX Parameters”
Get DMX Parameters: Retrieve and display latest settings
value.
Set DMX Parameters: Save settings
The following parameters can be adjusted:
Break Time (µsec): This can be set between 96 and 1355.
181 is the Default.
Mark After Break (MAB in µsec): This can be set between
10 and 1355. 106 is the Default.
Packet Refresh Rate (per sec): This can be set between 0 and 40. 40 is the Default.
Firmware
The Firmware update procedure can be used to:
Update to the latest feature set.
Reset DMX USB PRO Mk2 if it ever gets stuck or stops responding. (Error mode).
The following steps will explain firmware update procedure:
1.
Within EMU Firmware Tab, you will find current firmware
version of connected device. Below that is a drop down to
select a default firmware option or download a version
from the ENTTEC website and locate it manually with
‘Choose File’.
2.
After selecting the firmware file, click on the “Update
Firmware” button and let the update proceed. Do not
remove the USB until the update is complete.
3.
Once Finished, the page will automatically refresh with
confirmation message, and firmware version information
will be updated to reflect the updated firmware.