background image

 
 
 
 

 

 

PRO-DC1/2

 

Installation and Setup Guide

 

Issue:

 

002

 

 

Содержание PRO-DC1

Страница 1: ...PRO DC1 2 Installation and Setup Guide Issue 002 ...

Страница 2: ...8th Edition Regulation 444 MEASURES AGAINST ELECTROMAGNETIC DISTURBANCES imposes requirements for segregation of circuits IET Wiring Regulations 18th Edition Regulation 528 PROXIMITY TO WIRING SYSTEMS TO OTHER SERVICES imposes requirements for segregation of door entry access control circuits Band I 230VAC mains circuits Band II and other higher voltage circuits IET Wiring Regulations 18th Edition...

Страница 3: ...tions 6 4 Secure Lock Relay 7 Input Exit Switch Connections 7 Fail Open Lock Connection 7 Fail Closed Lock Connection 7 Lock Suppression 7 5 Call Panel Splitter 8 6 Call Panel Connections 8 7 Pairing Secure Lock Relay with Call Panel 9 Confirm Door No of Call Panel 9 Secure Lock Relay RS485 Address 9 8 Device List 10 ...

Страница 4: ...t The specification below shows the minimum cable requirements allow for extra cabling if redundancy is required Connection Cable A Door controller to each call panel 2x Cat5e or Cat6 B Lock Relay to locks 2x 1 5mm multi stranded flex or singles route through any exit fire switch or break glass for fail safe operation C Lock Relay to exit switch 1 Pair UTP 2 cores Cat5e or Cat6 D Lock Relay to fir...

Страница 5: ...GURE 2 1 Item Connection Detail Power Supply Unit PSU Section 3 Page 6 Secure Lock Relay Section 4 Page 7 Secure Lock Relay PRO DC2 only Call Panel Splitter Section 5 Page 8 Network Switch Section 6 Page 8 A B C D E C B A E D ...

Страница 6: ...Point Pre Wired 12V to Internal Devices Backup Battery Connections for Sealed Lead Acid Battery Output Voltage Adjustment SYSTEM VOLTAGE 13 8VDC Always test the output voltage Only adjust if required Fuse Holder Mains Supply Cable from Fused Spur 1 5mm Twin Earth LIVE BROWN NEUTRAL BLUE EARTH GREEN YELLOW Sheath A B C D E A B L N E B B L N E E A C D A ...

Страница 7: ...agnetic locks FIGURE 4 2 Fail Closed Lock Connection Connection for fail closed locks power to release e g electric strike FIGURE 4 3 Lock Suppression _ Lock Secure Lock Relay FIGURE 4 4 1N4007 DIODE FITTED AT LOCK Entrotec recommend locks with built in suppression If such a lock is not being used it is ESSENTIAL to fit suitable suppression as close to the lock as possible This prevents back EMF a...

Страница 8: ...485A RS485B 12VDC from Call Panel Splitter 1 Pair UTP 12v White 2 Pair UTP 0v Black Ethernet to Network Switch 1x Cat5e or Cat6 RJ45 T568B FIGURE 6 2 EIA TIA 568B COLOUR CODE 12VDC Connections to Call Panel 12v 0v RS485 Data to Call Panel FS1 FS4 Call Panel Supply Fuses 1 25 Amp Fast Acting PL5 Not Used PL1 PL4 Call Panel Connection Plugs A B C D E A B C Up to 90M A B C C D E A B ...

Страница 9: ... the Door No each Call Panel on a block should have a unique number FIGURE 7 1 Secure Lock Relay RS485 Address Each Secure Lock Relay must have the address corresponding to the last 2 digits within the Door No of the associated Call Panel o E g Door No 8001 RS485 address 1 Door No 8015 RS485 address 15 SW1 Switches 1 6 set the binary address 0 63 Switch 1 2 3 4 5 6 Binary Value 1 2 4 8 16 32 Addre...

Страница 10: ...Device List 10 8 Device List IP Address Block ID SIP ID Type Description 192 168 1 111 1 8001 Call Panel Ashwood Court Front Door ...

Страница 11: ...Notes 11 ...

Страница 12: ...Entrotec Ltd 5 Ashwood Court Oakbank Livingston EH53 0TL Telephone 01506 886 230 Support 01506 886 235 www entrotec com ...

Отзывы: