PRO-AC4

 

Installation and Setup Guide

 

Issue:

 

002

 

 

Содержание PRO-AC4

Страница 1: ...PRO AC4 Installation and Setup Guide Issue 002...

Страница 2: ...th Edition Regulation 444 MEASURES AGAINST ELECTROMAGNETIC DISTURBANCES imposes requirements for segregation of circuits IET Wiring Regulations 18th Edition Regulation 528 PROXIMITY TO WIRING SYSTEMS...

Страница 3: ...y Connections 6 4 Access Controller 7 4 1 Readers Connections 9 5 Lock Connections 10 5 1 Lock Distribution Board 10 5 2 Exit Switch Connections 10 5 3 Fail Open Lock Connection 11 5 4 Fail Closed Loc...

Страница 4: ...operation of equipment The specification below shows the minimum cable requirements allow for extra cabling if redundancy is required Connection Cable A Access controller to each call panel 1x Cat5e...

Страница 5: ...Overview 5 2 Overview FIGURE 2 1 Item Connection Detail Power Supply Unit PSU Section 3 Network Switch Section 6 Access Controller Section 4 Lock Distribution Board Section 5 A B C D D A C B...

Страница 6: ...Conductor Point Pre Wired 12V to Internal Devices Backup Battery Connections for Sealed Lead Acid Battery Output Voltage Adjustment SYSTEM VOLTAGE 13 8VDC Always test the output voltage Only adjust if...

Страница 7: ...Access Controller 7 4 Access Controller FIGURE 4 1 Ethernet Port Section 6 Readers Connections 1 4 Section 4 1 DC12V IN A B C B C A...

Страница 8: ...Access Controller 8 FIGURE 4 2 Relay Connections Section 5 6 PTE Connections Section 5 2 A B A B...

Страница 9: ...o Access Controller Red White Blue DC12V Black Blue GND Yellow White Orange RS485 B Purple Orange RS485 A Magnet for Tamper Switch Wall Bracket Connections to Access Controller See Table M3x6mm Screw...

Страница 10: ...ard DC12V IN Lock Connections 1 4 Lock supply and Relay Outputs Relay Loop Connections Pre connected FS1 Lock Supply Fuses 2 Amp Time Delay 5 2 Exit Switch Connections FIGURE 5 2 For double pole push...

Страница 11: ...ion Connection for fail open locks power to hold e g magnetic locks FIGURE 5 3 5 4 Fail Closed Lock Connection Connection for fail closed locks power to release e g electric strike FIGURE 5 4 NOTE Cha...

Страница 12: ...t adequate suppression may invalidate any warranty NOTE Entrotec supply 1N4007 diodes 5 6 Relay Interconnections The 4 lock connections by default are configured for fail open locks power to hold e g...

Страница 13: ...locks power to release e g electric strike Move the wire in the position shown in red to the position shown in green FIGURE 5 7 ADJUSTING RELAY INTERCONNECTION FOR FAIL CLOSED LOCKS 6 Network Connecti...

Страница 14: ...the steps below 1 Connect a laptop or PC to the same network as the Access Controller 2 Using the ePRO Config tool change the IP address of the PRO AC4 using the default credentials Username admin Pa...

Страница 15: ...Notes 15...

Страница 16: ...Entrotec Ltd 5 Ashwood Court Oakbank Livingston EH53 0TL Telephone 01506 886 230 Support 01506 886 235...