TUTORIALS
Using Valves to Control a Multi-Head Machine
202 |
P a g e
Copyright © 2021 BF ENTRON and/or its affiliates. All rights reserved
Product Model:
iPAK2v2
Firmware Version:
V2.10
May 22 | Doc No 700253-2
Step
Instruction
NetFlash
Tab
Program/Electrode
WAV Check Selection
1
Select
Program
0
Set
Electrode
to 0
Check the
WAV1
checkbox
2
Select
Program
1
Set
Electrode
to 0
Check the
WAV2
checkbox
3
Select
Program
2
Set
Electrode
to 0
Check the
WAV3
checkbox
4
Select
Program
3
Set
Electrode
to 0
Check the
WAV4
checkbox
Table 77: Instructions to Program the WAV Output Per Weld Program on Multi-Head Machine
In the example, each program must be selected individually, then initiated. Programs can be run in any order.
Figure 78: Weld Timing Diagram for Multi-Head Machine with Independent Initiation of Each Weld Program