background image

Entrematic PAS024AS(W)

1

2

3
4

8

5

6

7

TECHNICAL SPECIFICATIONS

1. cover 
2. radar 

antenna 

(wide field)

3. 

radar field size adjustment

4. IR-prism 

(2 m)

DESCRIPTION

Presence
Typical response time: <256 ms
Active infrared with background analysis
Spot diameter: 0.1 m (typ)
Number of spots: 24
Number of curtains: 2
From -4 ° to +4 ° (adjustable)
Solid-state-relay 
(free of potential, free of polarity)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
0.3 s to 1 s (not adjustable)
Typical: < 5 ms

ENGLISH

Opening & safety sensor 

for automatic sliding doors

5. main 

connector

6. IR-angle 

adjustment

7. 

push button for setup or DIP-setting confirmation

8. DIP-switch

12 V - 30 V DC -5%/+10% 

(to be operated from SELV compatible power supplies only)

< 2.2 W
1.8 m to 3 m
< 1 V : Log. L; > 10 V: Log. H (max. 30 V)
-25 °C to +55 °C
IP54
< 70 dB
20 years
EN 16005; EN 12978; EN IEC 62061SIL2, EN 61496-1 ESPE Type 2; EN ISO 13849-1
Pl «c»

 CAT.2 

(under the condition that the door control system monitors the sensor at least once per door cycle)

Supply voltage:
Power consumption:
Mounting height:
Sensitivity of the test input:
Temperature range:
Degree of protection:
Noise:
Expected lifetime:
Norm conformity:

Motion
Min. detection speed: 5 cm/s
Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm2
From 15 ° to 50 ° vertical (adjustable)
Solid-state-relay 
(free of potential, free of polarity)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
0.5 s

Detection mode:

Technology:

Angle:
Output:

Hold time output signal:
Response time on test request:

PAS024ASW: energy-saving unidirectional sensor 
PAS024AS: bidirectional sensor

User’s Guide for product version 0200 and higher
See product label for serial number

Specifications are subject to changes without prior notice. All values measured in specific conditions.

GREEN
LED

RED
LED

Содержание PAS024AS

Страница 1: ...N IEC 62061SIL2 EN 61496 1 ESPE Type 2 EN ISO 13849 1 Pl c CAT 2 under the condition that the door control system monitors the sensor at least once per door cycle Supply voltage Power consumption Mounting height Sensitivity of the test input Temperature range Degree of protection Noise Expected lifetime Norm conformity Motion Min detection speed 5 cm s Microwave doppler radar Transmitter frequency...

Страница 2: ... Check position of IR curtains with Spotfinder and adjust if necessary ANGLE Detection field width indicated according to conditions defined in EN 16005 and including dimension of test body CA Available as accessory INFRARED FIELD SAFETY WIDTH H W 2 20 m 2 30 m 2 50 m 2 55 m 3 00 m 2 80 m H W 2 20 m 1 20 m 2 50 m 1 40 m 3 00 m 1 60 m in standard presetting GREEN BROWN YELLOW WHITE PINK GREY RED2 BLUE...

Страница 3: ...s PRESETTINGS ENVIRONMENT RELAY R1 ACTIVATION SAFETY INSTRUCTIONS TIP Launch an ASSISTED SETUP to verify wiring position of the curtains and correct functioning of the sensor SETTINGS by DIP switch QUICK SETUP ASSISTED SETUP SETUP Step outside of the infrared field before launching a setup LONG 3s SHORT standard critical environment shopping street1 hospital2 standard extreme3 1 Can only be used if...

Страница 4: ...ush on the push button Cut and restore power supply If orange LED lights up again replace sensor Check the angle of the IR curtains Launch a new assisted setup Attention Do not stand in the detection field Change the activation mode of relay R1 DIP 4 Use a low energy prism if possible accessory Check the angle of the IR curtains Check if the sensor is fastened firmly Check position of prism and cove...