Service/Maintenance
Service and adjustments performed by your Entrematic Group-authorized representative will ensure
safe and proper operation of your automatic door unit.
Remember to keep “Service Log Book” and “Site Acceptance Test and Risk Assessment” documents
available. These are used together.
The table below shows the recommended interval in months, when to replace parts during preventive
maintenance.
Abusive
Environment
Cycles/hour in operation
Part number
Part
>100
<100
<10
High
traffic
Medium
traffic
Low
traffic
6
6
12
24
331003882
Vibration absorbers and oil plug
6
6
12
24
330000485BK/SI
PUSH/PUSH-335 service kit
6
6
12
24
330000486BK/SI
PULL/PULL-220 service kit
6
6
12
24
331003887
ST-V/H service kit
6
6
12
24
33655614
Limit switch
60
60
60
60
33655599
Capacitor
60
60
60
60
331004115
CSDB-230 control unit
60
60
60
60
600089
CSDA-S
60
60
60
60
600081
CSDA-F
Other products from Entrematic Group
•
Door Systems
•
Sliding doors
•
Automatic and manual activation units
11
Issue 2019-06-11
1004131-EMen-12.0
Содержание EM EMSW
Страница 1: ...Swing Door Operator EM EMSW User Manual Original instructions...