Configuring the terminal
MorphoAccess® SIGMA Lite Series terminals are standalone biometric systems which
offers advance features for access control. MorphoAccess® SIGMA Lite Series
terminals are equipped with a facility to support the MorphoAccess® and Bioscrypt
legacy systems.
When MorphoAccess® SIGMA Lite Series terminal is set in any of the legacy modes, it
supports the database structures and configurations of the selected legacy system.
When the terminal is booted for the first time, user can select any of the following
modes:
MorphoAccess® 500 or J Series legacy mode
MorphoAccess® SIGMA Lite Series terminal can be operated in MorphoAccess
®
500
or J series mode (also referred as Legacy Morpho). In this mode, the terminal will
support configurations and operations of MorphoAccess
®
500 series terminals.
Terminal can authenticate users enrolled in the MorphoAccess
®
500 series terminal,
using biometric check as well as contactless card. New users can also be enrolled in
MorphoAccess
®
500 series mode.
Once the product is configured in Legacy Morpho mode, the following methods can
be used to configure the terminal:
through the Ethernet interface (remote management)
through a Wi-Fi™ connection (license and dongle required)
Configuration procedures are described inside the MorphoAccess® SIGMA Lite Series
Administration Guide as follows:
Section 4: Terminal Configuration And Administration
Bioscrypt 4G Series legacy mode
MorphoAccess® SIGMA Lite Series can be operated in Bioscrypt 4G mode (also
referred as Legacy L1). In this mode, the terminal will support limited operations and
configurations that are done using Secure Admin application. The terminal in L1 mode
is able to authenticate the users enrolled on 4G terminals and contactless cards.
However it is not possible to enrol users in legacy L1 mode on MorphoAccess® SIGMA
Lite Series terminal.
In case, users are enrolled in MA5G mode, the user data cannot be exported when
terminal is in L1 mode.
Once the product is configured in Legacy L1 mode, the following methods can be
used to configure the terminal:
through the Ethernet interface (remote management)
through a Wi-Fi™ connection (license and dongle required)
www.TURNSTILES.us / www.entrapass.com / 8641 S. Warhawk Road, Conifer, CO 80433 / 303-670-1099
Содержание MorphoAccess SIGMA Lite Series
Страница 48: ...Section 5 User Interface www TURNSTILES us www entrapass com 8641 S Warhawk Road Conifer CO 80433 303 670 1099 ...
Страница 69: ...Annex 2 Bibliography www TURNSTILES us www entrapass com 8641 S Warhawk Road Conifer CO 80433 303 670 1099 ...
Страница 73: ...Annex 3 Support www TURNSTILES us www entrapass com 8641 S Warhawk Road Conifer CO 80433 303 670 1099 ...