Entes MPR-3 Series Скачать руководство пользователя страница 1

1

Network Anayzer 

User Manual

MPR-3 

Series

www.entes.eu

Содержание MPR-3 Series

Страница 1: ...1 Network Anayzer User Manual MPR 3 Series www entes eu...

Страница 2: ...ne Termination Resistance 13 OPERATING DEVICE 13 Measurement Screens 13 Current Voltage and Frequency Screens 14 Power and Power Factor Screens 15 Energy and Harmonic Screens 17 Minimum Maximum and De...

Страница 3: ...y current transformers which have reinforced insulation The power meter shall not be used for primary protection or applications where its failure can cause harm or death Please de energize the device...

Страница 4: ...Voltage 95 270 VAC DC Frequency Range 50 60 10 Hz Maximum Measured Current 5 5 A Maximum Measured Voltage 300 VAC L N 480 VAC L L Operating Temperature Range 10 70 C Storage Temperature Range 20 80 C...

Страница 5: ...er Factor o Total Active Power o Total Reactive Power o Total Apparent Power o Total Cos o Total Power Factor o Total Harmonic Distortion for Current THD I o Total Harmonic Distortion for Phase Phase...

Страница 6: ...n and display them on the LCD screen Thanks to the RTC clock chip and flash memory on the device the operations performed by the operator such as interruption records time and setting changes reset op...

Страница 7: ...7 MPR 3 Product Family Appearance and Interface The front view of the device is as follows Terminal Structures MPR 3X Series Rear Panel Model with Two Inputs Model with One Input and One Output...

Страница 8: ...ase Current input L3 Phase Current output MPR 3X PM Series Rear Panel 1 2 3 4 5 6 1 Voltage Inputs V1 1 Phase Voltage input V2 2 Phase Voltage input V3 3 Phase Voltage input N Neutral input 2 Supply I...

Страница 9: ...Indicates that the communication is active 12 Indicates whether the value is Cos or Power Factor 13 Indicates the unit of the value W kVAr MVA etc 14 Indicates the measured values of the corresponding...

Страница 10: ...it is used for monitoring Harmonic measurements on the Voltage Current screen and Energy measurements on the Power screen While in the menu screen it is used for moving downyards in a menu and decrea...

Страница 11: ...ection type 3P3W Three Phase Three Wire Connection As it is seen below three voltage and three current connections are established in this connection type ARON Connection Three voltage and two current...

Страница 12: ...ow the device displays the value measured at the current input connected to the first phase on its screen for other phases in the same value Connection Control After the connections of the device are...

Страница 13: ...irection 3 Reverse Phase 3 current direction 4 Reverse Voltage connection of Phase 1 and Phase 2 5 Reverse Voltage connection of Phase 1 and Phase 3 6 Reverse Voltage connection of Phase 2 and Phase 3...

Страница 14: ...ACK VIF VOLTAGE L N You can view the Phase Phase Voltage values measured for each phase on this screen The bottom line contains the measured frequency value NAME OF THE BUTTON DISPLAYED MEASUREMENT SC...

Страница 15: ...er Factor Screens You can view the Power and Power Factor values in this menu On this screen you can view the Total Power values active reactive apparent measured on your device NAME OF THE BUTTON DIS...

Страница 16: ...ains the total apparent power value NAME OF THE BUTTON DISPLAYED MEASUREMENT SCREEN DOWN P PF APPARENT POWER On this screen you can view the Power Factor inductive capacitive values measured for each...

Страница 17: ...s screen you can view the Total Harmonic Distortion Phase Phase values measured for each phase on your device NAME OF THE BUTTON DISPLAYED MEASUREMENT SCREEN UP E H THD L N On this screen you can view...

Страница 18: ...the last line on this screen NAME OF THE BUTTON DISPLAYED MEASUREMENT SCREEN UP E H IMPORT REACTIVE ENERGY You can view the Export Reactive Energy values in the last line on this screen NAME OF THE BU...

Страница 19: ...ATE Minimum Maximum and Demand Screens Please first select the related screen by V I F button in order to see the minimum and maximum values of current and voltage Then press SET button and you can se...

Страница 20: ...The bottom line contains the measured maximum frequency value NAME OF THE BUTTON DISPLAYED MEASUREMENT SCREEN SET MAX MIN MAX PHASE PHASE VOLTAGE On this screen you can view the Minimum Phase Phase Vo...

Страница 21: ...nt values measured for each phase on this screen NAME OF THE BUTTON DISPLAYED MEASUREMENT SCREEN SET MAX MIN MINIMUM CURRENT Please first select the related screen by the P PF button in order to see t...

Страница 22: ...ctive power value NAME OF THE BUTTON DISPLAYED MEASUREMENT SCREEN SET MAX MIN MAXIMUM ACTIVE POWER You can view the Minimum Active Power values measured for each phase on this screen The last line con...

Страница 23: ...ower demand value NAME OF THE BUTTON DISPLAYED MEASUREMENT SCREEN SET MAX MIN APPARENT POWER DEMAND On this screen you can view the Apparent Power Maximum Demand values measured for each phase The las...

Страница 24: ...s are accessed Factory default device menu password is 1234 Installation Settings of the Device The current transformer and voltage transformer ratio of the device installed in the system should be pr...

Страница 25: ...next setting with the SET button Voltage Transformer Presence Setting 1 By means of UP DOWN buttons determine whether there is any voltage transformer connected to the system by using Enable and Disab...

Страница 26: ...mer Secondary Setting 1 Select the secondary value of current transformer from 1A or 5A values by using UP DOWN buttons 2 Switch to the next setting by the SET button after adjusting the desired value...

Страница 27: ...minal operating voltage of the device can be selected from 25V to 300V 2 You can use the SET button for switching between the digits 3 Switch to the next setting by the SET button after adjusting the...

Страница 28: ...he SET button for switching between the digits 3 Switch to the next setting by the SET button after adjusting the desired value After completing the initial settings the device switches to the measure...

Страница 29: ...he menu by means of the BACK button Backlight Setting There are three different options for the display backlight setting a Always ON b Always OFF c Automatic When the automatic option is selected the...

Страница 30: ...Hour Setting The hour minute and second adjustments of the RTC Real Time Clock module of the device can be applied by pressing the SET button The phases of this process 1 Press the SET button while on...

Страница 31: ...with UP DOWN buttons 5 The entered date will be automatically saved while you are leaving the menu by pushing the BACK button Time Zone Setting 1 Press the SET button while you are on the Time Zone s...

Страница 32: ...at order 6 After the desired values are adjusted please press the SET button and leave this menu 7 Do not forget to save the adjusted settings before leaving the menu by means of the BACK button RS 48...

Страница 33: ...ired value by using UP DOWN buttons 4 Do not forget to save your settings before leaving the menu by means of the BACK button RS 485 Parity Setting The RS 485 communication parity of the device can be...

Страница 34: ...by means of the SET button while you are on the displayed selection screen 3 Adjust the desired value by using UP DOWN buttons 4 Do not forget to save your settings before leaving the menu by means of...

Страница 35: ...isplayed selection screen 3 Adjust the desired value by using the UP DOWN buttons 4 Do not forget to save your settings before leaving the menu by means of the BACK button Pulse Output Settings Pulse...

Страница 36: ...PULSE is selected on the screen 2 Choose the energy value according to the desired section which the device generates an output pulse as indicated in the screens above 3 Exit from the menu after comp...

Страница 37: ...on 4 Do not forget to save your settings before leaving the menu by means of the BACK button Pulse Output Inactive Time Duty Setting In this section the duration that the pulse will stay at the logic...

Страница 38: ...ect the parameter where the time counter will start 3 Switch to the next setting by the SET button after making your choice Then the level which this selected parameter will start the hour counter is...

Страница 39: ...buttons 3 Press the SET button after making your choice 4 Do not forget to save your settings before leaving the menu by means of the BACK button Selecting Alarm Parameters Follow the steps below for...

Страница 40: ...Operating Method Settings 1 Press the SET button for selecting the alarm operation method 2 In this mode select one of the following options a In window b Out window c Lower than d Higher than 3 When...

Страница 41: ...ve alarm parameters separately for 4 different alarms 5 Do not forget to save your settings before leaving the menu by means of the BACK button Hysteresis Setting of the Alarm In this mode the hystere...

Страница 42: ...g the SET button 6 The alarm is not released for the time where the parameter value is set here unless it exceeds the threshold hysteresis value 7 Adjust the desired time value in seconds by using UP...

Страница 43: ...and press the SET button 2 Select the Yes option for deleting by using tUP DOWN buttons in the Reset Demand section shown on the screen 3 Press the SET button 4 Do not forget to save your settings be...

Страница 44: ...eset menu and press the SET button 2 Select the Yes option for deleting by using DOWN buttons in the Reset Gen Energy section shown on the screen 3 Press the SET button 4 Do not forget to save your se...

Страница 45: ...rget to save your settings before leaving the menu by means of the BACK button Factory default pin is 1234 Changing the Pin Code 1 Press the SET button in the Change Pin screen of the System Menu 2 En...

Страница 46: ...ssage is displayed on the screen while exiting the menu 8 3 seconds after the software version of the device is displayed on the screen and device installation restore process starts Displaying the So...

Страница 47: ...addresses and access the details of the related record through the same tables A free software has been prepared to read the Record data inside the device and can be obtained from the web page Record...

Страница 48: ...ed as the oldest one By pressing the SET button you can respectively display the event s 1 Start date 2 Start time 3 End date 4 End time 5 Duration 6 Parameter 7 Source of the event 8 Value of the eve...

Страница 49: ...asurement accuracy Class 2 Active power measurement range 0 1 GW Reactive power measurement range 0 1 GVAr Apparent power measurement range 0 1 GVA Power consumption 4VA Active energy measurement ceil...

Страница 50: ...rmance class according to CEU 61557 12 according to KI Other additional specifications P 10 to 120 ln 0 5 Qa Qv 10 to 120 ln 1 Sa Sv 10 to 120 ln 1 Ea 0 to 99999999 kW h 0 5 Era Erv 0 to 99999999 kVar...

Страница 51: ...mpatibility EMC Part 4 4 Test and measurement tech niques Electrical fast transient burst immunity test Electromagnetic compatibility EMC Part 4 5 Test and measurement tech niques Surge immunity test...

Страница 52: ...52 Program Menu Map...

Страница 53: ...Cihazlar Imalat ve Ticaret A S Adr Dudullu OSB 1 Cadde No 23 34776 Umraniye ISTANBUL TURKIYE Tel 90 216 313 01 10 Fax 90 216 314 16 15 E mail contact entes eu Web www entes eu Call Center Technical Su...