Entes EVM-R3 Скачать руководство пользователя страница 1

RAIL MOUNTED DIGITAL VOLTMETER
EVM-R3 / EVM-R3C / EVM-R3S

Setting Instant Tripping Function (For EVM-R3C)

Press the 

set

 button.

Press 

up

 or 

down

 buttons until 

tP

 is

displayed.

Press the 

set

 button.

Press 

up

 or 

down

 buttons until desired

value is displayed

Press the 

set

 button.

Displaying and Deleting Tripping Number (For EVM-R3C)

Press the 

set

 button.

Press 

up

 or 

down

 buttons until 

OP

 is

displayed.

Press the 

set

 button.

Press up button to delete tripping
number, else do not press any button.

Press the 

set

 button.

Adjustment Contact Situation (For EVM-R3C)

Press the 

set

 button.

Press 

up

 or 

down

 buttons until 

CO

 is

displayed.

Press the 

set

 button.

Press 

up

 or 

down

 buttons until desired

value is displayed. (0: Normally open,

1: normally closed)

Press the 

set

 button.

Displaying Phase-Phase or Phase-Neutral Voltage (For EVM-R3S)

Press until 

desired voltage

 is displayed.

Escaping the Set Menu (For EVM-R3C)

If you do not want to change any

adjustment in the menu;
Press 

up

 or 

down

 buttons until 

ESC

 is

displayed.

Press the 

set

 button.

s  p

0

p

i

s   p

0   p

0  0  5
0  0  0

s  p

0

0  0  0

e  s  c

0  0  0

Precautions For Installation and Safe Use

Failure to follow those instructions will result in death or serious injury.

  Disconnect all power before working on equipment.

  When the device is connected to the network, do not remove the front

panel.

  Do not try to clean the device with solvent or the like. Only clean the

device with a dried cloth.

  Verify correct terminal connections when wiring.

   Electrical equipment should be serviced only by your compedent seller.

  Only for rack panel mounting.

No responsibility is assured by the manufacturer or any of its

subsidiaries for any consequences arising out of the use of this

material.

1

Setting Latch Function (For EVM-R3C)

Press the 

set

 button.

Press 

up

 or 

down

 buttons until 

lt

 is

displayed.

Press the 

set

 button.

Press 

up

 or 

down

 buttons until desired

value is displayed

Press the 

set

 button.

s  p

0

i

Setting of Delay Time (For EVM-R3C)

Setting of Set Point Value (For EVM-R3C)

EVM-R3 (Digital Voltmeter) :

EVM-R3 is designed for accurate measuring of the AC RMS voltage and for

saving the minimum and maximum values of the measured voltages. Minimum

and maximum values remain stored in the memory when the power supply is

off. This stored values can be read when the power is on. EVM-R3 can be used

with any application in which accurate voltage readings should be done between

10-600 V.

EVM-R3S (3-Phase Digital Voltmeter) :

EVM-R3S has the same operating principles as EVM-R3 but developed to

measure voltage in three-phase systems. By using the button on the front panel,

phase-phase (L1-L2, L1-L3, L2-L3) and phase-neutral (L1-N, L2-N, L3-N)

voltages can be selected and read from the display.

EVM-R3C (Setpointed Voltmeter) :

EVM-R3C has the same functions of the EVM-R3. In addition to these functions,

an over voltage level and “time delay” can be set. When the measured voltage

is over the set value, the output relay is activated at the end of the adjusted

time delay, generates an alarm signal and display starts blinking.

Minimum and Maximum Voltage :

The minimum and maximum voltage values are stored. User may read or delete

these values. Stored minimum and maximum voltage values remain stored,

when the power supply is off.

Setpoint (

SP

):

When the measured AC voltage between two points is over the setting value,

the output relay is activated in order to generate an error signal, at the end of

the delay time. If the AC voltage is 1.5 times of setting value, output relay is

activated without any delay. If the AC voltage value become lower the setting

value before the end of the delay time, the relay resets itself and no tripping

occurs.

Latch Function ( ):

In case of overvoltage the output relay is activated. Latch function is used to

select the output relay operation mode. Either “0” or “1” position may be selected.

   At position “0”:

 If the voltage is below the setting value, output relay releases

automatically, doesn’t need any reset.

  At position “1”:

 Even if the voltage is below the setting value, output relay

remains activated until the reset and releases only by pressing the “set” button.

Instant Tripping       :

If the AC voltage is 1.5 times of setting value, the output relay is activated without

any delay time. This function is user selectable.

   

At position ‘‘0’’:

 Instant tripping is OFF.

   

At position ‘‘1’’:

 Instant tripping is ON.

(

p

)

Press the 

set

 button.

Press 

up

 or 

down

 buttons until 

SP

 is

displayed.

Press the 

set

 button.

Press 

up

 or 

down

 buttons until voltage

Set Point value is displayed. (When 

up

 or

down

 buttons are continiously pressed,

the display change quickly.)

Press the 

set

 button.

s p

s   p

2  5  0

2  7  5

Press the 

set

 button.

Press 

up

 or 

down

 buttons until 

dt

 is

displayed.

Press the 

set

 button.

Press 

up

 or 

down

 buttons until desired

value is displayed. (When 

up

 or 

down

buttons are continiously pressed, the

display change quickly.)
Press the 

set

 button.

s  p

10.0

15.2

L1-N

L2-N

L3-N

L1-L2

L2-L3

L1-L3